摘要

Background In the present study we developed, evaluated in volunteers, and clinically validated an image acquisition stabilizer (IAS) for Sidestream Dark Field (SDF) imaging. Methods The IAS is a stainless steel sterilizable ring which fits around the SDF probe tip. The IAS creates adhesion to the imaged tissue by application of negative pressure. The effects of the IAS on the sublingual microcirculatory flow velocities, the force required to induce pressure artifacts (PA), the time to acquire a stable image, and the duration of stable imaging were assessed in healthy volunteers. To demonstrate the clinical applicability of the SDF setup in combination with the IAS, simultaneous bilateral sublingual imaging of the microcirculation were performed during a lung recruitment maneuver (LRM) in mechanically ventilated critically ill patients. One SDF device was operated handheld; the second was fitted with the IAS and held in position by a mechanic arm. Lateral drift, number of losses of image stability and duration of stable imaging of the two methods were compared. Results Five healthy volunteers were studied. The IAS did not affect microcirculatory flow velocities. A significantly greater force had to applied onto the tissue to induced PA with compared to without IAS (0.25 ± 0.15 N without vs. 0.62 ± 0.05 N with the IAS, p Conclusions The present study has validated the use of an IAS for improvement of SDF imaging by demonstrating that the IAS did not affect microcirculatory perfusion in the microscopic field of view. The IAS improved both axial and lateral SDF image stability and thereby increased the critical force required to induce pressure artifacts. The IAS ensured a significantly increased duration of maintaining a stable image sequence.
机译:背景技术在本研究中,我们开发了志愿者,对其进行了评估,并在临床上验证了用于侧流暗场(SDF)成像的图像采集稳定器(IAS)。方法IAS是一个可消毒的不锈钢环,可安装在SDF探针尖端周围。 IAS通过施加负压在成像组织上产生粘附力。在健康志愿者中评估了IAS对舌下微循环流速,诱发压力伪影(PA)所需的力,获取稳定图像的时间以及稳定成像的持续时间的影响。为了证明SDF装置与IAS结合的临床适用性,在机械通气危重患者的肺募集操作(LRM)期间,对微循环同时进行了双侧舌下成像。一台SDF设备是手持操作的;第二台装有IAS,并由机械臂固定在适当的位置。比较了两种方法的横向漂移,图像稳定性损失的次数和稳定成像的持续时间。结果对5名健康志愿者进行了研究。 IAS不会影响微循环流速。与不使用IAS相比,施加在组织上的PA产生的力要大得多(不使用IAS时为0.25±0.15 N,使用IAS时为0.62±0.05 N,p结论)本研究已证实使用IAS可以改善SDF通过证明IAS不会在微观视野内影响微循环灌注来成像,IAS改善了轴向和横向SDF图像的稳定性,从而增加了诱导压力伪影所需的临界力IAS确保了显着增加维持压力的持续时间稳定的图像序列。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号