In order to get some efficient microbial membrane, a Bacillus subtilis (BA1304) was isolated from wastewater, and was identified by the MicroStation System, and was used as the sensitive material for the BOD sensor (BODs) after being immobilized. Three immobilized mediators: polyethylene, sodiumalginate and polyacrylamidewere tested for choosing proper cell carriers. Furthermore, four temperature grads (25???°C, 30???°C, 35???°C and 37???°C) were studied to find the optimal working conditions. The result showed that the polyethylene was proven to be the most efficientmediator to the electrode in the presence of excess glucose/glutamic acid (GGA). The effective culture temperature was 35???°C for Bacillus subtilis by testing values in standard BOD solutions, which were estimated using the BODs with deviation less than 5%. The BOD values were determined using the sensor and compared favorablywith those determined by the conventional BOD5method.
机译:为了获得有效的微生物膜,从废水中分离出了枯草芽孢杆菌(BA1304),并通过MicroStation System进行了鉴定,并在固定后用作BOD传感器(BOD)的敏感材料。测试了三种固定的介体:聚乙烯,海藻酸钠和聚丙烯酰胺,以选择合适的细胞载体。此外,研究了四个温度等级(25℃,30℃,35℃和37℃)以找到最佳的工作条件。结果表明,在存在过量葡萄糖/谷氨酸(GGA)的情况下,聚乙烯被证明是电极的最有效介体。通过测试标准BOD溶液中的值,枯草芽孢杆菌的有效培养温度为35℃,该值是使用BOD估计的,偏差小于5%。使用传感器确定BOD值,并将其与常规BOD5方法确定的BOD值进行比较。