首页> 外文期刊>Biomedical Optics Express >Measurement of pulsatile total blood flow in the human and rat retina with ultrahigh speed spectral/Fourier domain OCT
【24h】

Measurement of pulsatile total blood flow in the human and rat retina with ultrahigh speed spectral/Fourier domain OCT

机译:超高速光谱/傅里叶域OCT测量人和大鼠视网膜中搏动性总血流量

获取原文

摘要

We present an approach to measure pulsatile total retinal arterial blood flow in humans and rats using ultrahigh speed Doppler OCT. The axial blood velocity is measured in an en face plane by raster scanning and the flow is calculated by integrating over the vessel area, without the need to measure the Doppler angle. By measuring flow at the central retinal artery, the scan area can be very small. Combined with ultrahigh speed, this approach enables high volume acquisition rates necessary for pulsatile total flow measurement without modification in the OCT system optics. A spectral domain OCT system at 840nm with an axial scan rate of 244kHz was used for this study. At 244kHz the nominal axial velocity range that could be measured without phase wrapping was ±37.7mm/s. By repeatedly scanning a small area centered at the central retinal artery with high volume acquisition rates, pulsatile flow characteristics, such as systolic, diastolic, and mean total flow values, were measured. Real-time Doppler C-scan preview is proposed as a guidance tool to enable quick and easy alignment necessary for large scale studies. Data processing for flow calculation can be entirely automatic using this approach because of the simple and robust algorithm. Due to the rapid volume acquisition rate and the fact that the measurement is independent of Doppler angle, this approach is inherently less sensitive to involuntary eye motion. This method should be useful for investigation of small animal models of ocular diseases as well as total blood flow measurements in human patients in the clinic.
机译:我们提出一种使用超高速多普勒OCT测量人类和大鼠的脉动性总视网膜动脉血流的方法。轴向血流速度是通过光栅扫描在一个平面上测量的,而流量是通过在整个血管区域上积分来计算的,而无需测量多普勒角度。通过测量视网膜中央动脉的流量,扫描区域可以非常小。与超高速相结合,该方法无需进行OCT系统光学器件的修改即可实现脉动总流量测量所需的高体积采集速率。这项研究使用了在840nm处具有244kHz轴向扫描速率的光谱域OCT系统。在244kHz时,无需相位缠绕即可测得的标称轴向速度范围为±37.7mm / s。通过以高体积采集速率重复扫描以视网膜中央动脉为中心的小区域,可以测量脉动血流特性,例如收缩压,舒张压和平均总血流值。提出了实时多普勒C扫描预览作为指导工具,可以快速,轻松地进行大规模研究所需的对准。由于算法简单且健壮,因此使用此方法可以完全自动化地进行流量计算的数据处理。由于快速的体积采集速率以及测量结果独立于多普勒角度的事实,这种方法本质上对非自愿眼动不敏感。这种方法对于在临床上对人类眼科疾病的小型动物模型进行调查以及总血流量测量很有用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号