This study aimed at investigating the removal of iron (Fe), zinc (Zn) and bacteria from steel making wastewater. Current density varying between 10 and 20 A/m(2) was applied. Hydraulic retention time (HRT) and sludge retention time (SRT) of 13.5 h and 10 d were maintained, respectively. Each run was carried out for 45 d. Fe and Zn concentrations in influent wastewater and treated effluent were measured by HACH LCK 321 and LCK 360 vials, respectively. Bacteria content was determined using colony forming unit (CFU). XRF was used to analyze the concentration of Fe and Zn on electrodes deposits and sludge precipitates. Results showed that Fe removal of 98.4 +/- 1.1%, 81.1 +/- 12.3%, and 38.8 +/- 4.2%, and Zn removal of 93.8 +/- 2.7%, 71.8 +/- 17.7%, and 50.1 +/- 17.2 % were reported at 10, 15, and 20 A/m(2), respectively. Bacteria was reported to have been completely removed by eMBR. Also, XRF analysis at 10 A/m(2) revealed higher Fe concentration on the electrodes deposits (214.5 +/- 8.7 and 3.0 +/- 0.1 g/kg on the cathode and anode, respectively) compared to sludge precipitate (48.8 +/- 4.9 g/kg). Similarly, XRF analysis at 10 A/m(2) revealed higher Zn concentration on the electrodes deposits (19.7 +/- 3.2 and 0.6 +/- 0.3 g/kg on the cathode and anode, respectively) compared to sludge precipitate (8.2 +/- 1.8 g/kg).
机译:这项研究旨在研究从炼钢废水中去除铁(Fe),锌(Zn)和细菌的方法。电流密度在10到20 A / m(2)之间变化。水力停留时间(HRT)和污泥停留时间(SRT)分别保持为13.5 h和10 d。每次运行进行45天。分别通过HACH LCK 321和LCK 360小瓶测量进水和处理后废水中的铁和锌浓度。使用菌落形成单位(CFU)测定细菌含量。 XRF用于分析电极沉积物和污泥沉淀物上的铁和锌的浓度。结果显示,铁去除率为98.4 +/- 1.1%,81.1 +/- 12.3%和38.8 +/- 4.2%,锌去除率为93.8 +/- 2.7%,71.8 +/- 17.7%和50.1 + / -分别以10、15和20 A / m(2)的速度报告了17.2%的电流。据报道,细菌已被eMBR完全清除。此外,在10 A / m(2)的XRF分析下,与污泥沉淀物(48.8 +)相比,电极沉积物上的铁浓度更高(分别在阴极和阳极上分别为214.5 +/- 8.7和3.0 +/- 0.1 g / kg)。 /-4.9克/千克)。同样,在10 A / m(2)的XRF分析下,与污泥沉淀物(8.2 +)相比,电极沉积物上的锌浓度较高(阴极和阳极分别为19.7 +/- 3.2和0.6 +/- 0.3 g / kg)。 /-1.8 g / kg)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号