首页> 外文期刊>Desalination and water treatment >Impact of organic fractions identified by SEC and fluorescence EEM on the hydraulic reversibility of ultrafiltration membrane fouling by secondary effluents
【24h】

Impact of organic fractions identified by SEC and fluorescence EEM on the hydraulic reversibility of ultrafiltration membrane fouling by secondary effluents

机译:通过SEC和荧光EEM鉴定的有机馏分对二级流出物超滤膜结垢的水力可逆性的影响

获取原文
获取原文并翻译 | 示例
       

摘要

Loss of membrane filtration performance due to organic fouling is still a significant drawback for the application of low-pressure membranes in tertiary wastewater treatment. The present study investigates the relevance of different organic fractions present in secondary effluents in terms of hydraulically reversible and irreversible fouling of hollow-fibre ultrafiltration membranes. A good correlation between the hydraulically reversible filtration resistance and the total organic biopoly-mer concentration according to size exclusion chromatography (SEC) was observed. Qualitatively biopolymers consist mainly of polysaccharides as well as proteins with high molecular weight. Poly-saccharides are retained by the membrane pores, but can be removed by simple UF backwashing. On the other hand, fluorescence excitation-emission matrix (EEM) analysis indicates that the extent of the hydraulically irreversible fouling correlates with the presence of protein-like substances. Removal of protein-like substances by biological slow sand filtration or chemical coagulation results in the significant reduction of the hydraulically irreversible fouling, which is presumably due to proteins in the molecular range of biopolymers. In contrast to the comparatively low sensitivity of colorimetric methods for the analysis of proteins and polysaccharides, the combined application of size exclusion chromatography and fluorescence EEM analysis is a promising tool for the determination of the organic fouling propensity of secondary effluents.
机译:由于有机结垢而导致的膜过滤性能的损失仍然是低压膜在第三级废水处理中的应用的重大缺点。本研究从中空纤维超滤膜的水力可逆性和不可逆性结垢方面研究了二级废水中不同有机物组分的相关性。根据尺寸排阻色谱法(SEC),观察到水力可逆过滤阻力与总有机生物聚合物浓度之间存在良好的相关性。定性地,生物聚合物主要由多糖以及高分子量蛋白质组成。多糖保留在膜孔中,但可以通过简单的UF反冲洗除去。另一方面,荧光激发-发射矩阵(EEM)分析表明,液压不可逆结垢的程度与蛋白样物质的存在有关。通过生物慢速砂滤或化学混凝去除蛋白质样物质可显着减少水力不可逆结垢,这可能是由于蛋白质在生物聚合物的分子范围内。比色法对蛋白质和多糖的分析灵敏度相对较低,尺寸排阻色谱法和荧光EEM分析相结合的应用是确定次级废水有机结垢倾向的有前途的工具。

著录项

  • 来源
    《Desalination and water treatment》 |2011年第3期|p.73-86|共14页
  • 作者单位

    Technische Universitaet Berlin, Chair of Water Quality Control, Sekr. KF 4, Str. Des 17. Juni 135, D-10623 Berlin, Germany;

    Technische Universitaet Berlin, Centre for Water in Urban Areas, Sekr. KF 4, Str. Des 17. Juni 135, D-10623 Berlin, Germany;

    Technische Universitaet Berlin, Chair of Water Quality Control, Sekr. KF 4, Str. Des 17. Juni 135, D-10623 Berlin, Germany;

    Technische Universitaet Berlin, Chair of Water Quality Control, Sekr. KF 4, Str. Des 17. Juni 135, D-10623 Berlin, Germany;

    King Abdullah University of Science and Technology, Water Desalination and Reuse Research Center, Thuwal 23955-6900, Saudi Arabia;

    Technische Universitaet Berlin, Chair of Water Quality Control, Sekr. KF 4, Str. Des 17. Juni 135, D-10623 Berlin, Germany;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    organic fouling; ultrafiltration; tertiary sewage treatment; fluorescence analysis; size exclusion chromatography; LC-OCD; EEM;

    机译:有机污垢超滤第三级污水处理;荧光分析;尺寸排阻色谱法;LC-OCD;脑电图;