首页> 外文期刊>Dental materials >Degree of conversion and in vitro temperature rise of pulp chamber during polymerization of flowable and sculptable conventional, bulk-fill and short-fibre reinforced resin composites
【24h】

Degree of conversion and in vitro temperature rise of pulp chamber during polymerization of flowable and sculptable conventional, bulk-fill and short-fibre reinforced resin composites

机译:纸浆室的转化程度和体外温度升温在可流动和尺寸的常规,块状填充和短纤维增强树脂复合材料的聚合过程中

获取原文
获取原文并翻译 | 示例
       

摘要

Objective. Determine the degree of conversion (DC) and in vitro pulpal temperature (PT) rise of low-viscosity (LV) and high-viscosity (HV) conventional resin-based composites (RBC), bulk-fill and short-fibre reinforced composites (SFRC).Methods. The occlusal surface of a mandibular molar was removed to obtain dentine thickness of 2 mm above the roof of the pulp chamber. LV and HV conventional (2 mm), bulk-fill RBCs (2-4 mm) and SFRCs (2-4 mm) were applied in a mold (6 mm inner diameter) placed on the occlusal surface. PT changes during the photo-polymerization were recorded with a thermocouple positioned in the pulp chamber. The DC at the top and bottom of the samples was measured with micro-Raman spectroscopy. ANOVA and Tukey's post-hoc test, multivariate analysis and partial eta-squared statistics were used to analyze the data (p 0.05).Results. The PT changes ranged between 5.5-11.2 degrees C. All LV and 4 mm RBCs exhibited higher temperature changes. Higher DC were measured at the top (63-76%) of the samples as compared to the bottom (52-72.6%) in the 2 mm HV conventional and bulk-fill RBCs and in each 4 mm LV and HV materials. The SFRCs showed higher temperature changes and DC% as compared to the other investigated RBCs. The temperature and DC were influenced by the composition of the material followed by the thickness.Significance. Exothermic temperature rise and DC are mainly material dependent. Higher DC values are associated with a significant increase in PT. LV RBCs, 4 mm bulk-fills and SFRCs exhibited higher PTs. Bulk-fills and SFRCs applied in 4 mm showed lower DCs at the bottom. (C) 2021 The Academy of Dental Materials. Published by Elsevier Inc.
机译:客观的。确定转化程度(DC)和体外丙位温度(PT)升高(LV)和高粘度(HV)常规树脂基复合材料(RBC),批量填充和短纤维增强复合材料( SFRC)。方法。除去颌骨摩尔的咬合表面,以获得纸浆室顶部上方2mm的牙牙厚度。常规(2 mm),将块状填充RBC(2-4mm)和SFRC(2-4 mm)施加在嵌入咬合表面上的模具(6mm内径)中。用位于纸浆室中的热电偶记录光聚合过程中的PT变化。用微拉曼光谱法测量样品顶部和底部的DC。 ANOVA和Tukey的后HOC测试,多变量分析和部分ETA平方统计用于分析数据(P <0.05)。结果。 PT变化范围在5.5-11.2℃之间。所有LV和4 mm RBC都表现出更高的温度变化。与2mM HV常规和体积填充RBC的底部(52-72.6%)和每4mM LV和HV材料中的底部(52-72.6%)相比,在样品的顶部(63-76%)测量较高的DC。与其他研究的RBC相比,SFRC显示出较高的温度变化和DC%。温度和DC受到材料的组成,然后是厚度的影响。重要性。放热温度升高和DC主要是依赖性的。较高的DC值与PT的显着增加相关。 LV RBCS,4毫米批量填充和SFRC显示出更高的PTS。在4 mm中施加的批量填充和SFRC显示底部的下部DCS。 (c)2021牙科材料学院。 elsevier公司出版

著录项

  • 来源
    《Dental materials》 |2021年第6期|983-997|共15页
  • 作者单位

    Univ Pecs Dept Restorat Dent & Periodontol 5 Dischka Gyozo St H-7621 Pecs Hungary;

    Univ Pecs Dept Gen & Phys Chem 6 Ifjusag St H-7624 Pecs Hungary|Janos Szentagothai Res Ctr 20 Ifjusag St H-7624 Pecs Hungary;

    Univ Pecs Dept Restorat Dent & Periodontol 5 Dischka Gyozo St H-7621 Pecs Hungary;

    Univ Pecs Med Sch 12 Szigeti St H-7624 Pecs Hungary;

    Janos Szentagothai Res Ctr 20 Ifjusag St H-7624 Pecs Hungary|Univ Pecs Fac Pharm Inst Organ & Med Chem 12 Szigeti St H-7624 Pecs Hungary;

    Univ Pecs Dept Oral & Maxillofacial Surg 5 Dischka Gyozo St H-7621 Pecs Hungary;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Pulpal temperature; Degree of conversion; Resin composite; Bulk-fill; Fiber-reinforced;

    机译:普拉尔温度;转化程度;树脂复合材料;批量填充;纤维增强;
  • 入库时间 2022-08-19 01:57:25

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号