...
首页> 外文期刊>Dental materials >Characterization of heat resistant hydraulic sealer for warm vertical obturation
【24h】

Characterization of heat resistant hydraulic sealer for warm vertical obturation

机译:耐热液压密封剂的耐热垂直溶液的特征

获取原文
获取原文并翻译 | 示例
           

摘要

Objective. Warm vertical compaction of gutta-percha is a technique that is used by most specialists for root canal obturation. The sealers currently available exhibit irriversible chemical changes when heated. New biologically active sealers that do not sustain irreversible changes when heated are an attractive alternative to be used with warm vertical compaction obturation technique. The aim of this study was to measure the heat generated by warm vertical compactors inside the root canal, characterize a newly developed root canal sealer at different temperatures and verify its suitability at the actual temperature window used clinically.Methods. The typical temperatures generated by two heat carriers in a root canal were assessed by thermocouples. Two premixed root canal sealers TotalFill BC and HiFlow BC (FKG, Switzerland) were allowed to set and they were characterized by scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS) and X-ray diffraction analysis (XRD) immediately after setting and by XRD after 28 days in physiological solution. The ion leaching in solution was assessed by inductively coupled plasma (ICP). The organic component was extracted in acetone and assessed by Fourier transform infrared spectroscopy (FT-IR) for both the unset sealer and sealer subjected to different temperatures. The heat profiles of both sealers were investigated by FT-IR and thermographic analysis.Results. None of the devices tested achieved the temperatures set on the dial. The highest temperatures were coronal followed by apical for both devices. The sealers were identical except for the vehicle. The inorganic components included tricalcium silicate, dicalcium silicate and zirconium oxide. No calcium hydroxide was produced by any of the sealers after immersion in physiological solution but calcium was released in solution. The chemistry of both sealers was modified when heated but both recovered when cooled.Significance. The heat carriers were unreliable and the heat generated inside the canal was not the same as the temperature set on the dial. Since both sealers had identical chemistry save for minimal modifications to the organic component and were both resistant to heat, TotalFill BC sealer is recommended for use with warm vertical compaction technique as it is cheaper and as effective as the HiFlow. (C) 2020 The Academy of Dental Materials. Published by Elsevier Inc. All rights reserved.
机译:客观的。 Gutta-Percha的热垂直压实是大多数专家用于根管闭塞的技术。当前可用的封口机在加热时具有难以置离的化学变化。当加热时,不维持不可逆变化的新型生物活性密封剂是具有温暖垂直压实闭合技术的有吸引力的替代方案。本研究的目的是测量根管内的温暖垂直压实机产生的热量,在不同温度下表征新开发的根管封口机,并验证其在临床上使用的实际温度窗口的适用性。方法。通过热电偶评估由根管中的两个热载体产生的典型温度。允许两种预混合的根管封口机TotalFill BC和Hiflow BC(FKG,瑞士)设置,它们的特征在于设置后立即扫描电子显微镜(SEM),能量分散光谱(EDS)和X射线衍射分析(XRD)在生理解决方案中28天后通过XRD。通过电感耦合等离子体(ICP)评估溶液中的离子浸出。有机组分在丙酮中萃取,并通过傅里叶变换红外光谱(FT-IR)评估,用于未经不同温度的未设置密封剂和密封剂。通过FT-IR和热原理分析研究了两个密封剂的热谱。结果。没有测试的设备达到拨号上设置的温度。最高温度是冠状,然后是两种装置的顶端。除了车辆之外,封口机相同。无机组分包括三钙,硅酸钠和氧化锆。在浸入生理溶液后,任何封口剂都不会产生氢氧化钙,但在溶液中释放钙。加热时,两种封口剂的化学改性,但在冷却时均恢复。重要性。热载体不可靠,并且在管内部产生的热量与表盘上的温度不同。由于两种封口机具有相同的化学化学,因此可以节省对有机成分的最小修改,并且耐热量都是耐热量,因此建议使用温暖的垂直压实技术使用,因为它与HIFLOW具有更便宜的垂直压实技术。 (c)2020牙科材料学院。由elsevier Inc.出版的所有权利保留。

著录项

  • 来源
    《Dental materials》 |2020年第9期|1183-1189|共7页
  • 作者单位

    Univ Birmingham Coll Med & Dent Sci Inst Clin Sci Sch Dent Birmingham W Midlands England;

    Univ Birmingham Coll Med & Dent Sci Inst Clin Sci Sch Dent Birmingham W Midlands England;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Root canal sealers; Warm vertical compaction; Sealer characterization;

    机译:根管封口机;温暖的垂直压实;封口器表征;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号