The reliability of standardized flexure strength testing procedures for a light-activated resin-based composite

机译:光活化树脂基复合材料的标准挠曲强度测试程序的可靠性

获取原文
获取原文并翻译 | 示例
           

摘要

Objectives: To investigate the differences in the reliability of three-point flexure strength (TFS) and bi-axial flexure strength (BFS) data of a dental resin-based composite (RBC) irradiated by a handheld or an oven light-curing unit (LCU). Methods: Three-point bar-shaped (25x2x2 mm~3) and bi-axial disc-shaped (12 mm diameter, 2 mm thick) specimens of Filtek™ Z250 were polymerized utilizing either a handheld (n = 20) or an oven-LCU (n = 20). The mean TFS and BFS, associated Weibull moduli and degree of conversion (DC) for each curing regime were obtained following 24 h immersion in a lightproof water bath maintained at 37±1℃. Results: A significant decrease in TFS (129±15 and 127±13 MPa) compared with BFS (140±12 and 148 ± 13 MPa) was identified for specimens irradiated with both LCU types (P<0.001). The Weibull moduli of TFS data associated with the handheld-was significantly decreased compared with the oven-LCU since confidence intervals did not overlap (7.5-9.4 and 9.5-10.6, respectively). In contrast, the Weibull moduli of the BFS data associated with either LCU were not significant (11.3-12.4 and 11.3-13.5). A significant decrease in the DC of three-point and bi-axial flexure specimens irradiated with the handheld compared with the oven-LCU was reported (P=0.031). Conclusions: The improved experimental reliability combined with the increased clinical relevance in specimen geometry of disc-compared with bar-shaped specimens may advocate bi-axial flexure testing methodology as the standard to assess the strength of light-activated dental RBCs. The differences in extent of polymerization of RBC specimens cured with either LCU were not consistent with an equivalent dose of light energy density. This phenomenon may be attributed to differences in polymerization efficiency associated with the quantity of useful light energy emitted from the handheld- compared with the oven-LCU.
机译:目的:研究手持式或烤箱光固化装置辐射的牙科树脂基复合材料(RBC)的三点弯曲强度(TFS)和双轴弯曲强度(BFS)数据的可靠性的差异( LCU)。方法:使用手持式(n = 20)或烤箱将三点条形(25x2x2 mm〜3)和双轴圆盘形(12 mm直径,2 mm厚)的Filtek™Z250标本聚合。 LCU(n = 20)。将每种TFS和BFS的平均TFS和BFS,相关的威布尔模量以及转化率(DC)在保持在37±1℃的不透光水浴中浸泡24小时后获得。结果:两种类型的LCU照射的标本的TFS(分别为129±15和127±13 MPa)和BFS(分别为140±12和148±13 MPa)显着降低(P <0.001)。与手持式LCU相比,与手持机相关的TFS数据的威布尔模量显着降低,因为置信区间不重叠(分别为7.5-9.4和9.5-10.6)。相反,与任一LCU相关的BFS数据的威布尔模量均不显着(11.3-12.4和11.3-13.5)。据报道,与烤箱LCU相比,用手持设备照射的三点和双轴挠性样品的DC显着降低(P = 0.031)。结论:改进的实验可靠性,以及与圆盘状样品相比,与圆盘状样品的样品几何形状相关的临床相关性增加,可能提倡使用双轴挠曲测试方法作为评估光活化牙科RBC强度的标准。用任一LCU固化的RBC标本的聚合程度差异与等效剂量的光能密度不一致。这种现象可能归因于与烤箱LCU相比,与手持式设备发出的有用光能数量相关的聚合效率差异。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号