首页> 外文期刊>Dental materials >Cross-link density evaluation through softening tests: Effect of ethanol concentration
【24h】

Cross-link density evaluation through softening tests: Effect of ethanol concentration

机译:通过软化测试评估交联密度:乙醇浓度的影响

获取原文
获取原文并翻译 | 示例
       

摘要

Objectives. The aim of this study was to investigate whether the ethanol concentration used would influence the outcomes obtained through softening tests when comparing light-activation modes. Methods. Disc specimens (n = 20) of Filtek Z250 and Filtek Z100 (3M ESPE) were light activated by standard (S) and pulse-delay (PD) modes. Initial Knoop hardness (KHN) measurements were performed 24 h after dry storage at 37 ℃. Half of the specimens (n = 10) of each resin-composite were stored in absolute ethanol (100%) and the other half in 75% ethanol solution, for 24 h at room temperature, and KHN was determined anew. Initial hardness data were submitted to Student's t-test (p = 0.05). Percentages of hardness decrease were analyzed by two-way ANOVA followed by pairwise Tukey's test (p = 0.05). The statistical analyses were performed separately for each resin-composite. Results. No statistically significant differences were observed between standard and pulse-delay modes for initial Knoop hardness values. After storage in 75% ethanol solution, KHN was decreased in all cases but no significant differences were detected between light-activation modes (Filtek Z250: PD = 12.6%, S = 13.5%; Filtek Z100: PD = 13.5%, S = 11.8%) regardless of the resin-composite tested. After absolute ethanol storage, higher decrease in KHN were observed. Samples light-activated by the PD mode (Filtek Z250 = 20.4% and Filtek Z100 = 16.9%) exhibited significantly higher percentage decrease of KHN than specimens light-activated by the standard mode (Filtek Z250 = 14.1% and Filtek Z100 = 8.8%), regardless of the resin-composite tested. Conclusion. The ethanol concentration affected the outcomes of the softening test.
机译:目标。这项研究的目的是研究在比较光激活模式时,所使用的乙醇浓度是否会影响通过软化测试获得的结果。方法。通过标准(S)模式和脉冲延迟(PD)模式对Filtek Z250和Filtek Z100(3M ESPE)的圆盘样品(n = 20)进行光激活。在37℃干燥保存24小时后进行首次努氏硬度(KHN)测量。每种树脂复合物的一半样品(n = 10)在室温下保存在无水乙醇(100%)中,另一半在75%乙醇溶液中保存24小时,然后重新测定KHN。初始硬度数据已提交给学生的t检验(p = 0.05)。硬度降低的百分比通过双向ANOVA和成对的Tukey检验进行分析(p = 0.05)。对每种树脂复合材料分别进行统计分析。结果。对于初始努氏硬度值,在标准和脉冲延迟模式之间未观察到统计学上的显着差异。在75%的乙醇溶液中储存后,所有情况下KHN均降低,但在光激活模式之间未发现显着差异(Filtek Z250:PD = 12.6%,S = 13.5%; Filtek Z100:PD = 13.5%,S = 11.8 %),与测试的树脂复合材料无关。绝对乙醇存储后,观察到KHN的进一步降低。 PD模式(Filtek Z250 = 20.4%和Filtek Z100 = 16.9%)光激活的样品比标准模式(Filtek Z250 = 14.1%和Filtek Z100 = 8.8%)光激活的样品表现出更高的KHN百分比降低。 ,无论所测试的树脂复合材料如何。结论。乙醇浓度影响软化测试的结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号