首页> 外文期刊>Dental materials >Interfacial corrections of maxillofacial elastomers for Kubelka-Munk theory using non-contact measurements
【24h】

Interfacial corrections of maxillofacial elastomers for Kubelka-Munk theory using non-contact measurements

机译:基于非接触测量的Kubelka-Munk理论的颌面弹性体的界面校正

获取原文
获取原文并翻译 | 示例
       

摘要

Objective. Reflectance measurements using a 45°/0° non-contact measuring system provide accurate data for translucent materials, yet the interfacial reflection corrections (IRCs) for Kubelka-Munk theory have not been evaluated using this system. The objective is to determine which IRC method for Kubelka-Munk theory (K-MT) models the spectral reflectance of pigmented maxillofacial elastomer (MFE) with least error.rnMethod. Samples at varying thicknesses of each of 19 shades of skin-colored maxillofacial elastomer were measured using this system on each of three backings. Reflectance values within the visible wavelength range for each shade were fit by non-linear regression to K-MT using different IRC methods: no IRC correction (No), IRC for opaque materials (Op) and IRC for translucent materials (Tr). Errors associated with each method were analyzed using repeated-measures ANOVA and a Bonferroni-corrected t-test.rnResults. Average error mean square values over all wavelengths were 0.00038 for K-MT with no IRC, 0.00023 with Op IRC, and 0.00015 with Tr IRC. The No method gave a statistically higher error than either the Op or Tr method at all analyzed wavelengths, and the Tr gave a lower error than the OP at all analyzed wavelengths between 450 and 600 nm. The predicted CIELAB values of all the shades tested fell into the range of human skin color space. Significance. Corrected Kubelka-Munk theory with the IRC for translucent materials proposed by Richmond provides higher accuracy on maxillofacial elastomer over the more important visible wavelengths. Color and translucency of maxillofacial elastomer can be predicted using corrected K-M theory.
机译:目的。使用45°/ 0°非接触式测量系统的反射率测量可提供半透明材料的准确数据,但尚未使用该系统评估Kubelka-Munk理论的界面反射校正(IRC)。目的是确定用于Kubelka-Munk理论(K-MT)的哪种IRC方法可以模拟误差最小的着色的颌面弹性体(MFE)的光谱反射率。使用该系统在三个背衬上分别测量了19种深浅肤色的面部颌面弹性体中每种厚度不同的样品。通过使用不同的IRC方法对K-MT进行非线性回归,将每种阴影的可见光波长范围内的反射率值拟合:无IRC校正(否),不透明材料的IRC(Op)和半透明材料的IRC(Tr)。使用重复测量方差分析和Bonferroni校正的t检验分析与每种方法相关的误差。对于没有IRC的K-MT,所有波长的平均误差均方值分别为0.00038,对于Op IRC为0.00023,对于Tr IRC为0.00015。在所有分析波长下,No方法的统计误差均高于Op或Tr方法,在450和600 nm之间的所有分析波长下,Tr的误差均低于OP方法。所有测试色调的预测CIELAB值都属于人类肤色空间范围。意义。 Richmond提出的带有IRC的半透明材料IRC修正Kubelka-Munk理论在更重要的可见波长范围内提供了颌面弹性体的更高准确性。颌面弹性体的颜色和半透明性可以使用校正后的K-M理论进行预测。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号