Objective. The aim of the present study was to evaluate and compare the elution of monomers from three different core build-up composite materials and correlate it with the degree of conversion.rnMethods. Three different core build-up composite materials (a chemically cured, a photo-cured, and a dual-cured) were tested. Ten samples (diameter: 4.5 mm and thickness: 2 mm) of each material were fabricated to evaluate the release of monomers. The photo-cured samples were polymerized for 40 s and the dual-cured samples for 20 s. The samples remained undisturbed for 10 min and then were stored in 1 ml of 75% ethanol at room temperature, and the storage medium was renewed after 24 h, 7 and 28 days. From the storage medium that was removed, samples were prepared and analyzed by LC-MS/MS. Additionally, four samples of each material were tested for the degree of conversion by using a FT-IR spectrometer. Results. The three composite materials differed significantly concerning the elution of monomers (BisGMA: p< 0.0001; TEGDMA: p< 0.0001; and Bisphenol A: p< 0.0001). A significantly higher amount of BisGMA and TEGDMA was released from the chemically cured composite compared to the other two materials. Between the photo-cured and the dual-cured material the latter eluted significantly higher amounts of BisGMA and TEGDMA. During the storage of the samples, the amounts of the eluted substances decreased. The degree of conversion of the chemically cured composite was significantly lower compared to the other two materials.rnSignificance. Using the present parameters, the photo-cured material released less monomer and therefore they might be less dangerous with respect to toxicological effects.
机译:目的。本研究的目的是评估和比较从三种不同的核心堆积复合材料中洗脱出的单体,并将其与转化率相关联。测试了三种不同的堆芯复合材料(化学固化,光固化和双固化)。每种材料制作十个样品(直径:4.5 mm,厚度:2 mm)以评估单体的释放。将光固化的样品聚合40 s,将双固化的样品聚合20 s。样品保持原样10分钟,然后在室温下存储在1 ml的75%乙醇中,并在24 h,7和28天后更新存储介质。从除去的存储介质中制备样品并通过LC-MS / MS分析。另外,通过使用FT-IR光谱仪测试每种材料的四个样品的转化度。结果。三种复合材料在单体洗脱方面有显着差异(BisGMA:p <0.0001; TEGDMA:p <0.0001;双酚A:p <0.0001)。与其他两种材料相比,从化学固化的复合材料中释放出大量的BisGMA和TEGDMA。在光固化和双固化材料之间,后者洗脱出的BisGMA和TEGDMA量明显更高。在样品存储期间,洗脱物质的量减少。与其他两种材料相比,化学固化复合材料的转化率明显更低。使用当前参数,光固化材料释放出较少的单体,因此就毒理学效应而言它们可能不太危险。

著录项

  • 来源
    《Dental materials》 |2009年第9期|1090-1095|共6页
  • 作者单位

    Department of Operative Dentistry and Periodontology, University Medical Center Freiburg,Dental School and Hospital, Hugstetter Strasse 55, 79106 Freiburg i. Br., Germany Department of Environmental Health Sciences, University Medical Center Freiburg,Breisacher Strasse 115 B, 79106 Freiburg i. Br., Germany;

    School of Dentistry, The University of Manchester, United Kingdom;

    Department of Environmental Health Sciences, University Medical Center Freiburg,Breisacher Strasse 115 B, 79106 Freiburg i. Br., Germany;

    Department of Operative Dentistry and Periodontology, University Medical Center Freiburg,Dental School and Hospital, Hugstetter Strasse 55, 79106 Freiburg i. Br., Germany;

    Department of Environmental Health Sciences, University Medical Center Freiburg,Breisacher Strasse 115 B, 79106 Freiburg i. Br., Germany;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    core build-up; monomers; high performance liquid; chromatography; mass spectrometry; elution;

    机译:核心积累;单体高性能液体色谱质谱;洗脱;
  • 入库时间 2022-08-18 03:47:30