首页> 外文期刊>Dental materials >Correlations between spectroradiometric and spectrophotometric colors of all-ceramic materials
【24h】

Correlations between spectroradiometric and spectrophotometric colors of all-ceramic materials

机译:全陶瓷材料的分光光度色和分光光度色之间的相关性

获取原文
获取原文并翻译 | 示例
       

摘要

Objectives. Color coordinates of translucent esthetic materials measured by traditional spectrophotometers (SP) would deviate from those measured by newly introduced spec-troradiometers (SR), which might simulate the clinical viewing condition better. This study aimed to determine the correlations in the SP- and SR-based color coordinates and color differences of all-ceramic materials. Methods. Specimens for seven A2 shade core ceramics (n = 7) and corresponding A2 and A3 shades veneer ceramics (n = 7) were fabricated in clinically relevant thicknesses (1.5 mm after layering). Color of layered specimens was measured according to the CIELAB color scale by a SP and a SR. Color differences (△E_(ab)~*) between the reference ceramics and the corresponding layered ceramics were calculated. Correlations between SP- and SR-based color coordinates and color difference values were determined (α = 0.05). Results. SR-based color coordinates were significantly different from the SP-based values; however, general shifting trends by the instrument were observed. SP- and SR-based CIE a*, b* and chroma values showed significant correlations (p<0.05); however, the CIE L* values and the color differences with the reference showed no significant correlations (p > 0.05). Significance. The color coordinates representing the hue attribute (CIE a*, b* and chroma) measured by a spectrophotometer and a spectroradiometer showed significant correlations; however, the color coordinates and the color difference values were significantly different by the instrument. Therefore, color coordinates and the color difference values based on different instruments should not be compared directly.
机译:目标。传统分光光度计(SP)测得的半透明美学材料的色坐标会与新引入的分光光度计(SR)所测得的颜色坐标有所偏离,这可能会更好地模拟临床观察情况。这项研究旨在确定所有陶瓷材料基于SP和SR的颜色坐标和色差之间的相关性。方法。制作了7种A2阴影芯陶瓷(n = 7)以及相应的A2和A3阴影单板陶瓷(n = 7)的样品,其临床相关厚度(分层后为1.5 mm)。通过SP和SR根据CIELAB色标测量分层样品的颜色。计算参考陶瓷和相应的层状陶瓷之间的色差(△E_(ab)〜*)。确定了基于SP和SR的颜色坐标与色差值之间的相关性(α= 0.05)。结果。基于SR的颜色坐标与基于SP的值显着不同;然而,观察到该仪器的总体变化趋势。基于SP和SR的CIE a *,b *和色度值显示出显着的相关性(p <0.05);然而,CIE L *值和与参考的色差显示无显着相关性(p> 0.05)。意义。用分光光度计和分光光度计测得的代表色相属性(CIE a *,b *和色度)的色坐标显示出显着的相关性;但是,该仪器的色坐标和色差值明显不同。因此,不应直接比较基于不同仪器的色坐标和色差值。

著录项

  • 来源
    《Dental materials》 |2010年第11期|p.1052-1058|共7页
  • 作者单位

    Department of Dental Materials and Center for Dental Materials, School of Dentistry, Kyung Hee University, Seoul, Republic of Korea;

    Department of Dental Materials and Center for Dental Materials, School of Dentistry, Kyung Hee University, Seoul, Republic of Korea;

    National Core Research Center for Nanomedical Technology, Yonsei University, Seoul, Republic of Korea;

    Denforus Co., Room 1202,1-B Diosuperium, 3001-2 Bangbae-Dong, Seocho-Gu, Seoul, Republic of Korea;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    all-ceramics; color coordinate; spectrophotometer; spectroradiometer;

    机译:全瓷颜色坐标;分光光度计分光辐射计;
  • 入库时间 2022-08-18 03:47:23

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号