首页> 外文期刊>Dental materials >The effect of disinfecting solutions on the dimensional stability of dental alginate impression materials
【24h】

The effect of disinfecting solutions on the dimensional stability of dental alginate impression materials

机译:消毒液对海藻酸盐印模材料尺寸稳定性的影响

获取原文
获取原文并翻译 | 示例
       

摘要

Objectives. Dimensional changes occur in set dental alginate impression materials when immersed in disinfecting solutions. In this contribution the dimensional changes of two algi-nates in two disinfecting solutions, and for two specimen thicknesses, have been studied. The results were analyzed theoretically. Methods. The dimensional changes of two commercial alginates (Blueprint Cremix and Hydrogum), have been measured, in distilled water and twd disinfecting solutions (Perform ID/sodium hypochlorite), using a traveling microscope, at 5 min intervals over a period of 1 h. Samples of simple geometry have been studied, namely rectangular strips with thicknesses of 1.5 and 3 mm, respectively. Results. In all cases, both alginates continuously shrank with time, in the three immersion liquids, over the hour of measurement, indicating transfer of water from the alginate into the external water or disinfecting solution. The t~(1/2) shrinkage plots were generally linear, but with an intercept on the t~(1/2) axis, indicating the possibility of an initial expansion at very short times. In most cases, the ratios of slopes for both thicknesses were 1.33-1.54, in contrast to the theoretical value of 2. Perform ID however gave anomalous results for the 1.5 mm thick samples. At 10 min their shrinkage was 1.34-1.72%, compared with -0.42% to 0.67% in the other two media. Significance. The effects of thickness observed were not in accord with simple Fickian theory because of the various ions diffusing into and out of the alginate. Moreover, the water content of the alginate decreased consequent on the cross-linking process.
机译:目标。当浸入消毒溶液中时,固定的藻酸盐牙科印模材料会发生尺寸变化。为此,研究了两种消毒剂中两种藻类的尺寸变化,以及两种样品的厚度。从理论上分析了结果。方法。在1 h的时间内,使用移动显微镜在蒸馏水和twd消毒溶液(Perform ID /次氯酸钠)中测量了两种商品藻酸盐(Blueprint Cremix和Hydrogum)的尺寸变化。已经研究了简单几何形状的样品,即厚度分别为1.5和3 mm的矩形条。结果。在所有情况下,在测量的一个小时内,两种藻酸盐在三种浸没液体中均会随时间连续收缩,表明水从藻酸盐转移到外部水或消毒液中。 t〜(1/2)的收缩图通常是线性的,但在t〜(1/2)轴上有一个截距,表明在很短的时间内有初始膨胀的可能性。在大多数情况下,两种厚度的斜率之比为1.33-1.54,与2的理论值相反。对1.5毫米厚的样品,执行ID可以得出异常结果。在10分钟时,它们的收缩率为1.34-1.72%,相比之下,其他两种介质的收缩率为-0.42%至0.67%。意义。观察到的厚度影响与简单的Fickian理论不一致,因为各种离子扩散到藻酸盐中或从藻酸盐中扩散出来。此外,在交联过程中,藻酸盐的水含量降低。

著录项

  • 来源
    《Dental materials》 |2012年第7期|749-755|共7页
  • 作者单位

    Department of Oral Growth and Development, Dental Physical Sciences in Dentistry Unit, Queen Mary, University of London, Barts and The London School of Medicine and Dentistry, Institute of Dentistry, London, United Kingdom;

    Department of Oral Growth and Development, Dental Physical Sciences in Dentistry Unit, Queen Mary, University of London, Barts and The London School of Medicine and Dentistry, Institute of Dentistry, London, United Kingdom;

    Department of Oral Growth and Development, Dental Physical Sciences in Dentistry Unit, Queen Mary, University of London, Barts and The London School of Medicine and Dentistry, Institute of Dentistry, London, United Kingdom;

    Department of Oral Growth and Development, Dental Physical Sciences in Dentistry Unit, Queen Mary, University of London, Barts and The London School of Medicine and Dentistry, Institute of Dentistry, London, United Kingdom;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    cross contamination; immersion disinfection; alginates; shrinkage; expansion; diffusion; disinfectants;

    机译:交叉感染;浸泡消毒;藻酸盐收缩扩张;扩散;消毒剂;
  • 入库时间 2022-08-18 03:47:08

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号