首页> 外文期刊>Current Cardiology Reviews >Synergy Between Direct Coronary Stenting Technique and Use of the Novel Thin Strut Cobalt Chromium Skylor™ Stent: the Mace in Follow Up Patients Treated with Skylor Stent [MILES Study]
【24h】

Synergy Between Direct Coronary Stenting Technique and Use of the Novel Thin Strut Cobalt Chromium Skylor™ Stent: the Mace in Follow Up Patients Treated with Skylor Stent [MILES Study]

机译:直接冠状动脉支架技术与新型薄支撑钴铬Skylor™支架的使用之间的协同作用:使用Skylor支架治疗的随访患者中的钉头锤[MILES研究]

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND: Despite significant improvements in stent platform, currently available bare-metal stentsn(BMS) are still associated with restenosis. Thin-strut design cobalt-chromium alloys hold the promise of improving resultsnof BMS, especially when implanted with direct technique. We performed an observational study to appraise outcomes ofnthe novel Skylor™ stent, stratifying outcomes according to stenting technique.nMETHODS and RESULTS: We included all consecutive patients undergoing coronary stenting with Skylor™ at 2 centersnbetween 2006 and 2009. The primary end-point was the long-term rate of major adverse cardiac events (MACE, i.e.ndeath, myocardial infarction (MI), coronary artery bypass grafting (CABG) or target vessel revascularization (TVR)). Asnpre-specified analysis, we compared patients undergoing direct stenting versus those stent implantation following predilation.nA total of 1020 patients were included (1292 Skylor™ stents), with procedural success obtained in 99%. Comparingnpatients undergoing direct stenting (66%) versus pre-dilation (34%) at 16±7 months of follow-up, MACE had occurrednin, respectively, 8% versus 14% (p=0.001), with death in 1% versus 2% (p=0.380), MI in 1% versus 2% (p=0.032),nCABG in 0.2% versus 2% (p=0.012), and TVR in 6% versus 9% [p=0.071]. Even at multivariable analysis with propensitynadjustment, direct stenting was associated with significantly fewer MACE [hazard ratio 0.60 [0.38-0.93], p=0.024].nCONCLUSIONS: This observational study suggests the presence of a beneficial synergy between direct coronary stentingntechnique and use of the novel thin-strut cobalt-chromium Skylor™ stent in real-world patients undergoing PCI.
机译:背景:尽管在支架平台上进行了重大改进,但当前可用的裸金属支架(BMS)仍与再狭窄有关。薄支撑设计的钴铬合金有望改善BMS的效果,尤其是在采用直接技术植入时。我们进行了一项观察性研究,以评估新型Skylor™支架的结局,并根据支架技术对结果进行分层。方法和结果:我们纳入了2006年至2009年之间在2个中心接受过Skylor™冠状动脉支架置入术的所有连续患者。重大心脏不良事件(MACE,全死,心肌梗死(MI),冠状动脉搭桥术(CABG)或目标血管血运重建(TVR))的长期发生率。作为预先指定的分析,我们比较了直接支架置入术和扩张后支架置入术的患者。n共纳入1020例患者(1292 Skylor™支架),手术成功率达99%。比较在16±7个月的随访中直接支架置入术(66%)与扩张前术(34%)的患者发生MACE的发生率分别为8%对14%(p = 0.001),死亡分别为1%和2 %(p = 0.380),MI分别为1%和2%(p = 0.032),nCABG分别为0.2%和2%(p = 0.012)和TVR分别为6%和9%[p = 0.071]。即使在进行倾向性调整的多变量分析中,直接支架置入术与显着降低的MACE也相关[危险比0.60 [0.38-0.93],p = 0.024]。n结论:这项观察性研究表明,直接冠状动脉支架置入术与术中使用之间存在有益的协同作用。新型薄支撑钴铬合金Skylor™支架,用于现实世界中接受PCI的患者。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号