Mixed potential theory suggests that the current required to cathodically protect steel in atmospherically exposed concrete is strongly dependent on the corrosion rate. At modest corrosion rates, typical design current densities would not achieve the level of cathodic polarisation required by commonly accepted protection criteria. However a cathodic current effectively lowers the unprotected corrosion rate by removing chloride ions and increasing the pH at the cathode. This work suggests that the prevention of further corrosion and the achievement of an adequate level of polarisation by a cathodic protection system is strongly dependent on these protective effects.
机译:混合电位理论表明,阴极保护大气暴露的混凝土中的钢所需的电流在很大程度上取决于腐蚀速率。在中等腐蚀速率下,典型的设计电流密度将无法达到公认的保护标准所要求的阴极极化水平。然而,阴极电流通过去除氯离子并增加阴极的pH值,有效地降低了未保护的腐蚀速率。这项工作表明,通过阴极保护系统防止进一步腐蚀以及实现足够的极化水平在很大程度上取决于这些保护作用。