首页> 外文期刊>Corrosion science >Localized coating failure of epoxy-coated aluminium alloy 2024-T3 in 0.5 M NaCl solutions: Correlation between coating degradation, blister formation and local chemistry within blisters
【24h】

Localized coating failure of epoxy-coated aluminium alloy 2024-T3 in 0.5 M NaCl solutions: Correlation between coating degradation, blister formation and local chemistry within blisters

机译:环氧树脂涂层的2024-T3铝合金在0.5 M NaCl溶液中的局部涂层失效:涂层降解,气泡形成与气泡内局部化学成分之间的相关性

获取原文
获取原文并翻译 | 示例
           

摘要

The role of pH on the nature and rate of the degradation of epoxy coatings on AA2024-T3 panels and subsequent corrosion of the substrate during immersion in NaCl solutions was investigated. In acidic solutions both blister formation and growth are rapid. Blisters become very large (≈1 cm) and new blisters appear to form for a certain time after exposure. Often very small (~ 0.1 mm) clear blisters surround these large blisters. Enhanced blister formation is due to irreversibly increased permeability of the coating for chloride ions and protons, the formation of more defect sites within the coating, and the weakening/dissolution of the oxide layer in low pH environments. In neutral pH solutions, coatings fail by forming one, or at most two, active blisters (red in color) within a few days of immersion with the time-to-failure dependent upon coating quality and thickness. Blister growth is a very slow process, and blister diameters rarely exceed a few millimeters even after several weeks. The accumulation of corrosion product within the blister slows down the corrosion rate and blister growth. The chloride concentration in the occluded solutions within the blister is significantly increased over the bulk concentration, and the pH is often in the acidic range. From electrochemical measurements it can be concluded that the anodic and cathodic reactions are confined to the blister and its immediate surroundings, rather than involving more of the surface over which the coating is intact. Based on corrosion morphology it is concluded that replated copper contributes to the overall cathodic reaction.
机译:研究了pH值对Aa2024-T3面板上环氧涂层的降解性质和速率以及浸入NaCl溶液中随后腐蚀基材的作用。在酸性溶液中,气泡的形成和生长都是快速的。暴露后一段时间内,水泡变得非常大(约1厘米),并且会形成新的水泡。通常,很小的透明水泡(约0.1毫米)包围着这些大的水泡。增强的水泡形成是由于涂层对氯离子和质子的渗透性不可逆转地提高,在涂层内形成更多缺陷部位以及在低pH环境中氧化层的弱化/溶解。在中性pH溶液中,涂层会因在浸没几天内形成一个或最多两个活性水泡(红色)而失效,失效时间取决于涂层的质量和厚度。水泡的生长是一个非常缓慢的过程,即使在几周后,水泡直径也很少会超过几毫米。泡罩内腐蚀产物的积累会减缓腐蚀速度和泡罩的生长。泡罩内被封闭的溶液中的氯离子浓度会比整体浓度显着增加,并且pH值通常在酸性范围内。从电化学测量可以得出结论,阳极和阴极反应仅限于水泡及其附近环境,而不是涉及涂层完整的表面的更多部分。根据腐蚀形态,可以得出结论:再填充铜有助于整体阴极反应。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号