Impact of climate on mockup for mass concrete incorporating pozzolans

机译:气候对掺有火山灰的大体积混凝土样机的影响

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Two mockup blocks were used to construct a temperature differential control plan (TDCP) for temperature differentials less than 25 degrees C (45 degrees F) and the climate effect was evaluated. The first block was without insulation and the second with a blanket and 25 mm (1-in) extruded polystyrene (XPS) board. The mixtures were of cement, slag and fly ash, and seven sensors were used. The test results showed that on a rainy day, the maximum temperature differential was greater than 30.9 degrees C (55.6 degrees F) without insulation. With a blanket and XPS board, the maximum temperature differential could be dramatically reduced to below 19 degrees C (34.2 degrees F), and enhanced the effects on mass concrete protection. TDCP had been used suitably and expediently in the construction duration at jobsite for two and half years long. (C) 2018 Elsevier Ltd. All rights reserved.
机译:使用两个样机模块构建温度差小于25摄氏度(45华氏度)的温差控制计划(TDCP),并评估了气候影响。第一块没有绝缘,第二块有毯子和25毫米(1英寸)挤出聚苯乙烯(XPS)板。混合物是水泥,矿渣和粉煤灰,使用了七个传感器。测试结果表明,在雨天,没有隔热层时,最大温差大于30.9摄氏度(55.6华氏度)。使用毯子和XPS板,最大温差可以显着降低至19摄氏度(34.2华氏度)以下,并增强了对大体积混凝土保护的效果。 TDCP已在施工现场的工期中适当且方便地使用了两年半。 (C)2018 Elsevier Ltd.保留所有权利。