首页> 外文期刊>Betonwerk + Fertigteil-Technik >Reduction of punching shear reinforcement: New experimental results on punching shear behavior of flat slabs with varying amount of punching shear reinforcement
【24h】

Reduction of punching shear reinforcement: New experimental results on punching shear behavior of flat slabs with varying amount of punching shear reinforcement

机译:减少冲切剪力:不同冲切剪力量对平板冲切剪力性能的新实验结果

获取原文
获取原文并翻译 | 示例
           

摘要

With introduction of Eurocode 2 in Germany, the punching shear design provisions for flat slabs were revised. In consequence of limited anchorage conditions of punching shear reinforcement elements in flat slabs depending on the effective depth, only a reduced steel strength may be used in the calculation of the steel contribution. Due to the lack of systematic tests and safety related concerns, the amount of punching shear reinforcement in flat slabs within the 1st and 2nd row was significantly increased in German Annex of Eurocode 2 (EC2NA) compared to the general Eurocode 2. The results of existing punching tests on flat slabs can be used to evaluate the code equations for punching shear capacity without shear reinforcement (Fig. (a)) and maximum punching shear capacity (Fig. (d)). Nevertheless, due to the lack of systematic test series on flat slabs with a failure inside the shear-reinforced zone (Fig. (b,c)), an evaluation of the code provisions for the design of the shear reinforcement has not yet been possible.
机译:随着在德国引入Eurocode 2,对平板的冲剪设计规定进行了修订。由于取决于有效深度的限制,在平板中冲切抗剪加固元件的锚固条件有限,在计算钢含量时只能使用降低的钢强度。由于缺乏系统的测试和与安全相关的问题,与常规的欧洲法规2相比,欧洲法规2的德国附件(EC2NA)中第一排和第二排平板中的冲切剪切钢筋的数量大大增加。可以在平板上进行冲孔试验,以评估无剪切增强的冲切剪切力(图(a))和最大冲切剪切力(图(d))的代码方程式。然而,由于缺乏对平板进行系统测试的一系列措施,而在钢筋内部(图(b,c))出现故障,因此尚无法评估抗剪设计规范的规定。 。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信