首页> 外文期刊>Computer methods in biomechanics and biomedical engineering >Zeroing of six-component handrim dynamometer for biomechanical studies of manual wheelchair locomotion
【24h】

Zeroing of six-component handrim dynamometer for biomechanical studies of manual wheelchair locomotion

机译:六分量手摇测功机的调零,用于手动轮椅运动的生物力学研究

获取原文
获取原文并翻译 | 示例
       

摘要

A six-component handrim dynamometer (HRD) is a dynamometer that rotates around the wheel axle during measurements. For this kind of dynamometer, static zero level calibration is insufficient because the proportion of the forces (i.e. handrim weight and centrifugal force) measured by each sensor varies according to the angular position and velocity of the dynamometer. The dynamic calibration presented in this paper is based on the direct correction of the sensor signals using Fourier's polynomials that take into account the influences of both the handrim weight distribution on the sensors with respect to the wheel's angular position and the effect of the wheel's angular velocity. When these corrections were applied to the signals produced by the sensors while the HRD was rotating and no effort was being exerted on the handrim, the calculated forces and torques remained close to zero, as expected. Based on these results, the wheel dynamometer can be confidently used for studying manual wheelchair locomotion under various real conditions. The method could also be applied in other situations in which a dynamometer rotates during measurements.
机译:六分量手轮测功机(HRD)是一种在测量过程中围绕轮轴旋转的测功机。对于这种测力计,静态零位校准是不够的,因为每个传感器测得的力的比例(即手轮重量和离心力)随测力计的角位置和速度而变化。本文提出的动态校准基于使用傅立叶多项式直接校正传感器信号的方法,该多项式考虑了轮辋重量分布对传感器相对于车轮角位置的影响以及车轮角速度的影响。当在HRD旋转时对传感器产生的信号进行这些校正时,在手缘上没有施加任何力时,所计算的力和扭矩将保持接近零的预期。基于这些结果,车轮测功机可以放心地用于研究各种实际条件下的手动轮椅运动。该方法还可以应用于测功机在测量过程中旋转的其他情况。

著录项

  • 来源
  • 作者单位

    Clermont Universite, F-63000 Clermont-Ferrand, France,Laboratoire d'Informatique, de Modelisation et d'Optimisation des Systemes, Universite Blaise Pascal, F-63000 Clermont-Ferrand, France,Unite Mixte de Recherche 6158, Laboratoire d'Informatique, de Modelisation et d'Optimisation des Systemes, Centre National de la Recherche Scientifique, Complexe scientifique des Cezeaux, B.P. 10125, F-63173 Aubiere Cedex, France;

    Clermont Universite, F-63000 Clermont-Ferrand, France,Laboratoire d'Informatique, de Modelisation et d'Optimisation des Systemes, Universite Blaise Pascal, F-63000 Clermont-Ferrand, France,Unite Mixte de Recherche 6158, Laboratoire d'Informatique, de Modelisation et d'Optimisation des Systemes, Centre National de la Recherche Scientifique, Complexe scientifique des Cezeaux, B.P. 10125, F-63173 Aubiere Cedex, France;

    Universite de Bordeaux, F-33000 Bordeaux, France,Laboratoire de Mecanique Physique, Universite Bordeaux 1, F-33000 Bordeaux, France,Unite Mixte de Recherche 5469, Laboratoire de Mecanique Physique, Centre National de la Recherche Scientifique, F-33400 Talence, France;

    Clermont Universite, F-63000 Clermont-Ferrand, France,Laboratoire d'Informatique, de Modelisation et d'Optimisation des Systemes, Universite Blaise Pascal, F-63000 Clermont-Ferrand, France,Unite Mixte de Recherche 6158, Laboratoire d'Informatique, de Modelisation et d'Optimisation des Systemes, Centre National de la Recherche Scientifique, Complexe scientifique des Cezeaux, B.P. 10125, F-63173 Aubiere Cedex, France;

    Clermont Universite, F-63000 Clermont-Ferrand, France,Laboratoire d'Informatique, de Modelisation et d'Optimisation des Systemes, Universite Blaise Pascal, F-63000 Clermont-Ferrand, France,Unite Mixte de Recherche 6158, Laboratoire d'Informatique, de Modelisation et d'Optimisation des Systemes, Centre National de la Recherche Scientifique, Complexe scientifique des Cezeaux, B.P. 10125, F-63173 Aubiere Cedex, France;

    Universite de Bordeaux, F-33000 Bordeaux, France,Laboratoire de Mecanique Physique, Universite Bordeaux 1, F-33000 Bordeaux, France,Unite Mixte de Recherche 5469, Laboratoire de Mecanique Physique, Centre National de la Recherche Scientifique, F-33400 Talence, France;

    Clermont Universite, F-63000 Clermont-Ferrand, France,Laboratoire d'Informatique, de Modelisation et d'Optimisation des Systemes, Universite Blaise Pascal, F-63000 Clermont-Ferrand, France,Unite Mixte de Recherche 6158, Laboratoire d'Informatique, de Modelisation et d'Optimisation des Systemes, Centre National de la Recherche Scientifique, Complexe scientifique des Cezeaux, B.P. 10125, F-63173 Aubiere Cedex, France;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    dynamometer; zero level; calibration; wheelchair; rehabilitation; biomechanics;

    机译:测力计零级校准;轮椅;复原;生物力学;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号