For the passage of utility ducts and/or pipes, openings often need to be created in the web of a reinforced concrete (RC) beam. Such a web opening can lead to a significant decrease in the ultimate load (i.e., strength) of the beam due to the reduced cross-sectional area and/or the severing of some of the existing steel reinforcement (particularly stirrups). In such cases, an externally-bonded fibre-reinforced polymer (FRP) strengthening system may be installed around the web opening to ensure the safety of the weakened beam. While existing experimental and numerical studies have provided useful information on the structural behaviour of RC beams with an FRP-strengthened web opening, this paper presents a theoretical study on the strength of such beams. First, a relatively simple, iterative numerical procedure (referred to as the iterative method) based on the static method of plastic limit analysis for predicting the plastic limit load (i.e., strength) of RC beams with an FRP-strengthened web opening is proposed, and then a closed-form, algebraic strength equation (referred to as the strength model) for such beams is established as a simplified approach of the iterative method. The accuracy of the proposed iterative method and strength model is verified with test results.
机译:对于公用管道和/或管道的通过,通常需要在钢筋混凝土(RC)梁的纤维网中产生开口。由于减小的横截面积和/或一些现有的钢筋(特别是镫形件),这种卷绕的卷筒纸可能导致光束的最终负载(即强度)的显着降低。在这种情况下,可以在卷筒纸开口周围安装外部粘合的纤维增强聚合物(FRP)强化系统,以确保弱化光束的安全性。虽然现有的实验和数值研究提供了有关RC光束的结构行为的有用信息,但是本文提出了这种梁的强度的理论研究。首先,提出了一种基于用于预测具有FRP加强的网页开口的RC光束的塑料极限分析的静态分析静态方法(即,称为迭代方法)的相对简单的迭代的数控程序(称为迭代方法),然后建立闭合形式的这种梁的代数强度方程(称为强度模型)作为迭代方法的简化方法。通过测试结果验证了所提出的迭代方法和强度模型的准确性。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号