Purpose This paper aims to analyze and investigate the performance of an improved fault detection and identification (FDI) method based on multiple criteria, applied to six-switch three-phase inverter (SSTPI)-fed induction motor (IM) drives under both single and multiple open insulated-gate bipolar transistors(IGBT) faults.Design/methodology/approach This paper proposes an advanced diagnostic method for both single and multiple open IGBT faults dedicated to SSTPI-fed IM drives considering five distinct faulty operating conditions as follows: a single IGBT open-circuit fault, a single-phase open-circuit fault, a non-crossed double fault in two different legs, a crossed double fault in two different legs and a three-IGBT open-circuit fault. This is achieved because of the introduction of a new diagnosis variable provided using the information of the slope of the current vector in (-) frame. The proposed FDI method is based on the synthesis and the analysis, under both healthy and faulty operations, of the behaviors of the introduced diagnosis variable, the three motor phase currents and their normalized average values. Doing so, the developed FDI method allows a best compromise of fast detection and precision localization of IGBT open-circuit fault of the inverter.Findings Simulation works, carried out considering the implementation of the direct rotor flux oriented control in an IM fed by the conventional SSTPI, have proved the high performance of the advanced FDI method in terms of fast fault detection associated with a high robustness against false alarms, against speed and load torque fast variations and against the oscillations of the DC-bus voltage in the case of both healthy and faulty operations.Research limitations/implications This work should be extended considering the validation of the obtained simulation results through experiments.Originality/value Different from other FDI methods, which suffer from a low diagnostic effectiveness for low load levels and false alarms during transient operation, this method offers the potentialities to overcome these drawbacks because of the introduction of the new diagnosis variable. This latter, combined with the information provided from the three motor phase currents and their normalized average values allow a more efficient detection and identification of IGBT open-circuit fault.
机译:目的本文旨在分析和研究基于多标准的改进的故障检测和识别(FDI)方法的性能,该方法适用于单开关和双开关下的六开关三相逆变器(SSTPI)馈电感应电动机(IM)驱动器设计/方法/方法本文针对SSTPI馈送的IM驱动器提出了一种针对单开和多开IGBT故障的高级诊断方法,该方法考虑了以下五个不同的故障操作条件: IGBT开路故障,单相开路故障,两个不同分支的非交叉双故障,两个不同分支的交叉双故障和三IGBT开路故障。这是由于引入了新的诊断变量而实现的,该诊断变量使用(-)帧中当前矢量的斜率信息提供。所提出的FDI方法是基于在运行状况良好和故障状态下对引入的诊断变量,三个电动机相电流及其归一化平均值的行为进行综合和分析的结果。这样做,开发出的FDI方法可以最大程度地兼顾逆变器IGBT开路故障的快速检测和精确定位功能。发现仿真工作,考虑了在常规馈送的IM中实现直接转子磁通定向控制的实现SSTPI已证明先进的FDI方法具有很高的性能,在快速故障检测方面具有很高的鲁棒性,可以有效地防止误报,速度和负载转矩快速变化以及在两种情况下均能防止直流母线电压波动研究的局限性/含义应当通过实验验证所获得的仿真结果的有效性来扩展这项工作。原创性/价值与其他FDI方法不同,该方法对低负载水平的诊断效率较低,并且在瞬态运行期间会产生误报,由于引入了这种方法,因此有潜力克服这些缺点新的诊断变量。后者与从三个电动机相电流提供的信息及其标准化平均值相结合,可以更有效地检测和识别IGBT开路故障。

著录项

  • 来源
    《Compel》 |2019年第2期|616-641|共26页
  • 作者单位

    SES, Elect Dept, Power Elect & Drives, Sfax, Tunisia|SES, Res CEMLab Lab, Sfax, Tunisia;

    SES, Electromech Engn Dept, Power Elect & Drives, Sfax, Tunisia|SES, Power Elect & Drives, Sfax, Tunisia;

    SES, CEMLab Lab, Sfax, Tunisia;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Improved FDI method; IM drives; SSTPI;

    机译:改进的FDI方法;IM驱动器;SSTPI;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号