首页> 外文期刊>Communications in Numerical Methods in Engineering >Finite element modeling, validation, and parametric investigations of a retinal reattachment stent
【24h】

Finite element modeling, validation, and parametric investigations of a retinal reattachment stent

机译:视网膜复位支架的有限元建模,验证和参数研究

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

A new retinal reattachment surgical procedure is based on a stent that is deployed to press the retina back in place. An eye-stent finite element model studied the strain induced by the stent on retina. Finite element model simulations were performed for several stent geometric configurations (number of loops, wire diameter, and intraocular pressure). The finite element model was validated against experiment. Parametric studies demonstrated that stents could be successfully designed so that the maximum strain would be below permanent damage strain threshold of 2%.
机译:一种新的视网膜复位手术方法是基于一个支架,该支架被部署为将视网膜压回原位。眼支架有限元模型研究了支架在视网膜上引起的应变。对几种支架的几何构型(环数,线径和眼压)进行了有限元模型仿真。对有限元模型进行了实验验证。参数研究表明,可以成功设计支架,以使最大应变低于永久损伤应变阈值2%。