首页> 外文期刊>Chinese physics >Study of tungsten wire array Z-pinch implosion on Qiang-Guang I facility
【24h】

Study of tungsten wire array Z-pinch implosion on Qiang-Guang I facility

机译:强广一厂钨丝阵列Z箍缩内爆研究

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The main results of investigation on the tungsten wire array Z-pinch implosion experiment performed on QiangGuang I facility in 2003 are reported in this paper. A set of diagnostic equipments including an x-ray power meter (XRPM), a 1D spatial-temporal x-ray meter and a pinhole camera was used to study implosion process and x-ray radiation characteristics of the tungsten wire array. In the experiment, the maximum x-ray yield of 36.6kJ was obtained for an optimizing load with a diameter of 8mm. and a length of 20mm, which consists of 32 5-mu m-diameter tungsten wires. The experimental results show that the region of x-ray emission decreased at a rate of 6.4 X 10(6)cm/s by analysing the data of the 1D spatial-temporal x-ray meter. It also shows that the peak time of x-ray radiation was prior to the time when plasmas were compressed into a near-axis region.
机译:本文报道了2003年在强光一厂进行的钨丝阵列Z-捏爆破实验的主要结果。使用一套诊断设备,包括X射线功率计(XRPM),一维时空X射线计和针孔照相机,来研究钨丝阵列的内爆过程和X射线辐射特性。在实验中,对于直径为8mm的优化负载,获得的最大X射线产量为36.6kJ。长度为20mm,由32根5微米直径的钨丝组成。实验结果表明,通过分析一维时空X射线仪的数据,X射线的发射区域以6.4 X 10(6)cm / s的速率减小。它还表明,X射线辐射的峰值时间早于将等离子体压缩到近轴区域的时间。