首页> 外文期刊>Chemosphere >Semipermeable membrane device (SPMD) for monitoring PCDD and PCDF levels from a paper mill effluent in the Androscoggin River, Maine, USA
【24h】

Semipermeable membrane device (SPMD) for monitoring PCDD and PCDF levels from a paper mill effluent in the Androscoggin River, Maine, USA

机译:半透膜装置(SPMD),用于监测美国缅因州安德罗斯科金河造纸厂废水中的PCDD和PCDF含量

获取原文
获取原文并翻译 | 示例
           

摘要

Paper mill effluents may contain polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dib-enzofurans (PCDFs) that are normally generated due to chlorinated bleaching of pulp and paper. We used the semipermeable membrane device (SPMD) to monitor PCDD/F levels upstream and downstream of a paper mill on the Androscoggin River, in Jay (ME). Following the 36 day deployment, SPMD dialysis and cleanup, the samples were analyzed by HRGC/HRMS. Total concentrations of PCDD/Fs in SPMDs (sum of all tetra-through octachlorinated congeners) ranged from 4.71 pg g~(-1) to 26.26 pg g~(-1). Five out of the targeted 17 toxic congeners were detected, including: 2,3,7,8-TCDF; 1,2,3,7,8-PeCDF; 2,3,4,7,8-PeCDF; 1,2,3,4,6,7,8-HpCDD and OCDD. Permeability reference compounds (PRCs) were used for in situ calibration of the SPMD sampling rate (R_s). In all sites, water concentrations were the highest for OCDD (0.081-0.103 pg l~(-1)), and the lowest for 1,2,3,7,8-PeCDF (0.005-0.009 pg l~(-1)). There was not a consistent pattern of upstream-downstream gradient in the PCDD/F levels. This suggested that processes other than the mill in Jay (multiple sources, river dynamics) governed the flux of PCDD/Fs in the sampling locations. The SPMD results were validated by comparison to other studies on the Androscoggin River and elsewhere, confirming the potential of the device as a useful monitoring technique for PCDD/Fs in large river systems.
机译:造纸厂的废水中可能含有多氯化二苯并对二恶英(PCDD)和多氯化二苯并呋喃(PCDF),通常是由于纸浆和纸张的氯化漂白而产生的。我们使用半透膜设备(SPMD)来监视Jay(ME)的Androscoggin河上造纸厂上游和下游的PCDD / F水平。在部署36天,进行SPMD透析和清理之后,通过HRGC / HRMS对样品进行了分析。 SPMD中PCDD / Fs的总浓度(所有四至八氯代同类物的总和)范围从4.71 pg g〜(-1)到26.26 pg g〜(-1)。在目标17种有毒同类物中检测到5种,包括:2,3,7,8-TCDF; 1,2,3,7,8-PeCDF; 2,3,4,7,8-PeCDF; 1,2,3,4,6,7,8-HpCDD和OCDD。渗透率参考化合物(PRC)用于SPMD采样率(R_s)的原位校准。在所有站点中,OCDD的水浓度最高(0.081-0.103 pg l〜(-1)),而1,2,3,7,8-PeCDF最低(0.005-0.009 pg l〜(-1) )。在PCDD / F水平上没有一致的上游-下游梯度模式。这表明,杰伊工厂以外的过程(多种来源,河流动力学)决定了采样位置PCDD / F的通量。通过与Androscoggin河和其他地方的其他研究进行比较,对SPMD的结果进行了验证,证实了该设备作为大型河流系统PCDD / Fs有用监测技术的潜力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号