首页> 外文期刊>Chemosphere >Effects of frequency and duty cycle of pulsating direct current on the electro-dewatering performance of sewage sludge
【24h】

Effects of frequency and duty cycle of pulsating direct current on the electro-dewatering performance of sewage sludge

机译:脉动直流频率和占空比对污水污泥电脱水性能的影响

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Electro-dewatering of sewage sludge with pulsating direct current (PDC-dewatering) was conducted to investigate the effects of pulsating frequency (0.01-60 Hz) and duty cycle (DTC) (20-100%) on sludge dewatering. The results indicated that both the frequency and DTC showed marked influences on electro-dewatering. Compared with the condition under the stable direct current (SDC-dewatering) of 30 V, the filtrate discharged from PDC-dewatering (at DTC of 40-60% and frequency of 30 Hz) was about 8% higher than that from SDC-dewatering. At DTC of 40%, the sludge electro-dewatering performance was promoted when the frequency increased from 0.01 Hz to 30 Hz. Compared with SDC-dewatering, PDC-dewatering can effectively mitigate ohmic heating. Layered tests were also conducted to investigate the differences of SDC- and PDC-dewatering in the distributions of water, pH, organic matters, zeta potential and conductivity in the upper, middle and lower layer of sludge cake. The results indicated that the variation tendencies of these parameters were similar between SDC- and PDC-dewatering, but the water, organic matters and charged ions in sludge cake were more homogeneously distributed during PDC-dewatering than SDC-dewatering. In addition, the anodic pH of PDC-dewatering was higher than that of SDC-dewatering, suggesting the potential of mitigating anodic corrosion during PDC-dewatering. Finally, energy consumptions of PDC- and SDC-dewatering were calculated and compared. The effects of frequency and DTC on energy consumption were investigated. PDC-dewatering was found to be more energy efficient than that of SDC-dewatering, making PDC-dewatering a promising electro-dewatering technology in future. (C) 2019 Elsevier Ltd. All rights reserved.
机译:进行污水污泥的电脱水,进行脉动直流(PDC-脱水),以研究脉动频率(0.01-60Hz)和占空比(DTC)(20-100%)对污泥脱水的影响。结果表明,频率和DTC都显示出对电脱水的显着影响。与30V的稳定直流(SdC-脱水)下的条件相比,从PdC-脱水(40-60%的DTC和30Hz的DTC)的滤液比来自SDC-脱水的40-60%和频率为40-60%。 。在40%的DTC,当频率从0.01Hz增加到30Hz时,促进了污泥电脱水性能。与SDC-脱水相比,PDC-脱水可以有效地减轻欧姆加热。还进行了分层试验以研究水,pH,有机物质,Zeta电位和下层污泥蛋糕中下层和下层的水分布中Sdc和Pdc-脱水的差异。结果表明,在PdC-脱水期间,SdC和PdC-脱水之间这些参数的变异趋势在SdC-和Pdc-脱水之间类似,但在Pdc-脱水期间,污泥饼中的水,有机物质和带电离子比SDC-脱水更均匀地分布。此外,PdC-脱水的阳极pH高于SDC-脱水的阳极pH,表明​​在PDC-脱水期间减轻阳极腐蚀​​的可能性。最后,计算并比较了PDC-和SDC-脱水的能量消耗。研究了频率和DTC对能量消耗的影响。发现Pdc-脱水比SDC脱水更能节能,使PDC-脱水未来是有希望的电脱水技术。 (c)2019 Elsevier Ltd.保留所有权利。

著录项

  • 来源
    《Chemosphere》 |2020年第3期|125372.1-125372.12|共12页
  • 作者单位

    Donghua Univ Sch Environm Sci & Engn 2999 North Renmin Rd Shanghai 201620 Peoples R China;

    Donghua Univ Sch Environm Sci & Engn 2999 North Renmin Rd Shanghai 201620 Peoples R China;

    Donghua Univ Sch Environm Sci & Engn 2999 North Renmin Rd Shanghai 201620 Peoples R China;

    Donghua Univ Sch Environm Sci & Engn 2999 North Renmin Rd Shanghai 201620 Peoples R China;

    Donghua Univ Sch Environm Sci & Engn 2999 North Renmin Rd Shanghai 201620 Peoples R China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Sewage sludge; Electro-dewatering; Frequency; Duty cycle; Pulsating voltage;

    机译:污水污泥;电脱水;频率;占空比;脉动电压;