首页> 外文期刊>Chemosphere >Temporal and spatial variation of trace elements in atmospheric deposition around the industrial area of Puchuncavi-Ventanas (Chile) and its influence on exceedances of lead and cadmium critical loads in soils
【24h】

Temporal and spatial variation of trace elements in atmospheric deposition around the industrial area of Puchuncavi-Ventanas (Chile) and its influence on exceedances of lead and cadmium critical loads in soils

机译:智利Puchuncavi-Ventanas工业区周围大气沉积物中微量元素的时空变化及其对土壤铅和镉临界负荷超标的影响

获取原文
获取原文并翻译 | 示例
           

摘要

Fractionation of elemental contents in atmospheric samples is useful to evaluate pollution levels for risk assessment and pollution sources assignment We present here the main results of long-term characterization of atmospheric deposition by using a recently developed atmospheric elemental fractionation sampler (AEFS) for major and trace elements monitoring around an important industrial complex located in Puchuncavi region (Chile). Atmospheric deposition samples were collected during two sampling campaigns (2010 and 2011) at four sampling locations: La Greda (LG), Los Maitenes (LM), Puchuncavi (PU) and Valle Alegre (VA). Sample digestion and ICP-MS gave elements deposition values (Al, As, Ba, Cd, Co, Cu, Fe, K, Mn, Pb, Sb, Ti, V and Zn) in the insoluble fraction of the total atmospheric deposition. Results showed that LG location, the closest location to the industrial complex, was the more polluted sampling site having the highest values for the analyzed elements. PU and LM were the next more polluted and, finally, the lowest elements concentrations were registered at VA. The application of Principal Component Analysis and Cluster Analysis identified industrial, traffic and mineral-crustal factors. We found critical loads exceedances for Pb at all sampling locations in the area affected by the industrial emissions, more significant in LG close to the industrial complex, with a trend to decrease in 2011, whereas no exceedances due to atmospheric deposition were detected for Cd. (C) 2015 Elsevier Ltd. All rights reserved.
机译:大气样品中元素含量的分级有助于评估污染水平,以进行风险评估和污染源分配。在此,我们使用最新开发的主要和痕量大气元素分级采样器(AEFS),介绍了大气沉积物长期表征的主要结果位于智利Puchuncavi地区重要工业园区周围的元素监测。在两个采样活动(2010年和2011年)期间,在四个采样地点分别收集了大气沉积样品:拉格莱达(LG),洛斯梅特尼斯(LM),普琴查维(PU)和瓦莱阿莱格里(VA)。样品消解和ICP-MS在总大气沉积的不溶部分中给出元素沉积值(Al,As,Ba,Cd,Co,Cu,Fe,K,Mn,Pb,Sb,Ti,V和Zn)。结果表明,LG位置(最靠近工业园区的位置)是污染最严重的采样点,其分析元素的值最高。 PU和LM的污染更严重,最后,在VA处元素的浓度最低。主成分分析和聚类分析的应用确定了工业,交通和矿物地壳因素。我们发现,在受工业排放影响的区域内所有采样点,铅的临界超标都超过了极限,而在靠近工业园区的LG中,铅的超标更为明显,2011年有下降的趋势,而镉的大气沉积未探测到超标。 (C)2015 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号