首页> 外文期刊>Calcified Tissue International >Comparative Study on Measured Variables and Sensitivity to Bone Microstructural Changes Induced by Weightlessness Between In Vivo and Ex Vivo Micro-CT Scans
【24h】

Comparative Study on Measured Variables and Sensitivity to Bone Microstructural Changes Induced by Weightlessness Between In Vivo and Ex Vivo Micro-CT Scans

机译:体内和体外Micro-CT扫描失重引起的测量变量和对骨微结构变化敏感性的比较研究

获取原文
获取原文并翻译 | 示例
           

摘要

Depending on the experimental design, micro-CT can be used to examine bones either in vivo or ex vivo (excised fresh or formalin-fixed). In this study we investigated if differences exist in the variables measured by micro-CT between in vivo and ex vivo scans and which kind of scan is more sensitive to the changes of bone microstructure induced by simulated weightlessness. Rat tail suspension was used to simulate the weightless condition. The same bone from either normal or tail-suspended rats was scanned by micro-CT both in vivo and ex vivo (fresh and fixed by formalin). Then, bone mineral density (BMD) and microstructural characteristics were analyzed. The results showed that no significant differences existed in the microstructural parameters of trabecular bone among in vivo, fresh, and formalin-fixed bone scans from both femurs and tibias, although BMD exhibited differences. On the other hand, most parameters of the tail-suspended rats measured by micro-CT deteriorated compared with controls. Ex vivo scanning appeared to be more sensitive to bone microstructural changes induced by tail suspension than in vivo scanning. In general, the results indicate that values obtained in vivo and ex vivo (fresh and fixed) are comparable, thus allowing for meaningful comparison of experimental results from different studies irrespective of the type of scans. In addition, this study suggests that it is better to use ex vivo scanning when evaluating bone microstructure under weightlessness. However, researchers can select any type of scan depending upon the objective and the demands of the experiment.
机译:取决于实验设计,微型CT可用于体内或离体检查(新鲜或福尔马林固定的骨头)。在这项研究中,我们调查了在体内和离体扫描之间通过micro-CT测量的变量是否存在差异,以及哪种扫描方式对模拟失重引起的骨微结构变化更敏感。大鼠尾部悬吊被用来模拟失重状态。通过micro-CT在体内和离体(新鲜和福尔马林固定)对来自正常或尾巴悬吊大鼠的相同骨骼进行扫描。然后,分析了骨矿物质密度(BMD)和显微组织特征。结果显示,尽管BMD表现出差异,但在股骨和胫骨的体内,新鲜和福尔马林固定的骨扫描中,小梁骨的微结构参数没有显着差异。另一方面,与对照相比,通过微型CT测量的尾部悬吊大鼠的大多数参数恶化。与体内扫描相比,离体扫描似乎对尾部悬吊引起的骨微结构变化更敏感。通常,结果表明体内和离体(新鲜和固定)获得的值是可比较的,因此无论扫描类型如何,都可以有意义地比较来自不同研究的实验结果。此外,这项研究表明,在评估失重状态下的骨微结构时,最好使用离体扫描。但是,研究人员可以根据实验的目的和要求选择任何类型的扫描。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号