首页> 外文期刊>Building and Environment >Airflow analysis in an air conditioning room
【24h】

Airflow analysis in an air conditioning room

机译:空调室内的气流分析

获取原文
获取原文并翻译 | 示例
       

摘要

The aim of superior air conditioning system is no longer constrained to advancing the efficiency of cooling machine, but includes the study of airflow with the assistance of the distribution of several significant parameters. A simple numerical study of the turbulent flow over an enclosed air conditioning system was not practicable a few decades ago since the computer facilities were not sufficient. In this paper, a standard office room was taken up for simulation. Temperature and velocity distribution over various virtual planes for different locations of the air conditioner blower were analyzed to achieve the maximum comfort for the occupant. With Fluent, as solution tool, k-epsilon and Reynolds stress models for turbulence flow were used for the analysis. The different locations of blower placement are analyzed for better comfort of occupant in the room and it is found that the occupant will experience most comfort if the air Conditioner blower is placed on location Ⅱ compared to the other two locations. This work can also be extended to a more complex air conditioning system like in the industries, hospitals as well as the gigantic shopping malls.
机译:优质空调系统的目标不再局限于提高冷却机的效率,而是包括借助几个重要参数的分布来研究气流。由于计算机设备不足,几十年前对封闭式空调系统中的湍流进行简单的数值研究是不可行的。在本文中,使用了一个标准办公室进行模拟。分析了空调鼓风机不同位置的各种虚拟平面上的温度和速度分布,以为乘员提供最大的舒适感。使用Fluent作为求解工具,使用k-ε和Reynolds湍流应力模型进行分析。分析了鼓风机放置的不同位置,以使房间中的乘客获得更好的舒适感,并且发现,与其他两个位置相比,如果将空调鼓风机放置在位置Ⅱ上,则乘员将获得最大的舒适感。这项工作还可以扩展到更复杂的空调系统,例如在工业,医院以及大型购物中心中。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号