The method of distributing the outdoor air in classrooms has a major impact on indoor air quality and thermal comfort of pupils. In a previous study, ([11] Karimipanah T, Sandberg M, Awbi HB. A comparative study of different air distribution systems in a classroom. In: Proceedings of Roomvent 2000, vol. Ⅱ, Reading, UK, 2000. p. 1013-18; [13]Karimipanah T, Sandberg M, Awbi HB, Blomqvist C. Effectiveness of confluent jets ventilation system for classrooms. In: Idoor Air 2005, Beijing, China, 2005 (to be presented).) presented results for four and two types of air distribution systems tested in a purpose built classroom with simulated occupancy as well as computational fluid dynamics (CFD) modelling. In this paper, the same experimental setup has been used to investigate the indoor environment in the classroom using confluent jet ventilation, see also ([12]Cho YJ, Awbi HB, Karimipanah T. The characteristics of wall confluent jets for ventilated enclosures. In: Proceedings of Roomvent 2004, Coimbra, Portugal, 2004.) Measurements of air speed, air temperature and tracer gas concentrations have been carried out for different thermal conditions. In addition, 56 cases of CFD simulations have been carried to provide additional information on the indoor air quality and comfort conditions throughout the classroom, such as ventilation effectiveness, air exchange effectiveness, effect of flow rate, effect of radiation, effect of supply temperature, etc., and these are compared with measured data.
机译:在教室中分配室外空气的方法对室内空气质量和学生的热舒适度有重大影响。在先前的研究中,([11] Karimipanah T,Sandberg M,Awbi HB。对教室中不同空气分配系统的比较研究。载于:Roomvent 2000年会议记录,第二卷,英国雷丁,2000年,第1013页。 -18; [-18] Karimipanah T,Sandberg M,Awbi HB,Blomqvist C.教室内融合射流通风系统的有效性,发表于:Idoor Air 2005,中国北京,2005(待发表)。在专用教室中测试了两种类型的空气分配系统,它们具有模拟的占用率以及计算流体动力学(CFD)建模。在本文中,使用相同的实验装置通过汇流射流通风来研究教室的室内环境,另请参见[[12] Cho YJ,Awbi HB,Karimipanah T.通风围墙壁汇流射流的特性。 :Roomvent的会议记录,2004年,葡萄牙科英布拉,2004年。)已经针对不同的热条件进行了空气速度,空气温度和示踪气体浓度的测量。此外,我们进行了56个CFD模拟案例,以提供有关整个教室的室内空气质量和舒适条件的其他信息,例如通风效果,空气交换效果,流速的影响,辐射的影响,供应温度的影响,等,并将其与测量数据进行比较。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号