In China, adding space heating in residential buildings is normally scheduled at the end of October each year, with heat supplied by district heating systems. This paper describes a field study of thermal comfort conducted in Harbin during the winter from 2009 to 2010 before and after the space heating is added. The aim is to study human responses to thermal conditions in the two periods in cold climates. 23 buildings in six communities were investigated. 199 occupants from 135 families and 174 occupants from 104 families participated in the two surveys during the two periods, respectively. The neutral air temperature before adding the space heating is 25.1 ℃, while during the space heating, it is 20.4 ℃. The clothing insulation is 0.77 clo and 0.88 clo, respectively. If they were 0.88 clo instead of 0.77 clo before adding the space heating, the neutral air temperature should be 21.1 ℃. Before and during space heating, more than 80% felt acceptable at the air temperature range between 17.5-24.0 ℃ and 19.0-26.5 ℃ for the two periods. The residents' physiological acclimation may contribute to the differences. The preferred temperature is within the range of 23.0-24.0 ℃ and 21.5-24.0 ℃, respectively. The preferred humidity is 47.7% and 40.5% during the two surveys. People felt cold generally before heating, while they felt comfortable at the same temperature range during space heating period. People often felt dry during heating when the relative humidity is lower than 30%, while they felt comfortable at the same relative humidity before heating.
机译:在中国,通常计划于每年的10月底在住宅中增加空间供热,而热量则由区域供热系统提供。本文介绍了在2009年至2010年冬季在哈尔滨市进行空间加热之前和之后进行的热舒适性的现场研究。目的是研究人类在寒冷气候的两个时期对热条件的反应。对六个社区的23栋建筑物进行了调查。在两个时期中,分别来自135个家庭的199位居民和104个家庭的174位居民参加了两次调查。添加空间加热之前的中性空气温度为25.1℃,而在空间加热期间的中性空气温度为20.4℃。衣物隔热层分别为0.77 clo和0.88 clo。如果在添加空间加热器之前为0.88 clo,而不是0.77 clo,则中性空气温度应为21.1℃。在两个时间段内,在空间加热之前和期间,在17.5-24.0℃和19.0-26.5℃的气温范围内,超过80%的温度可接受。居民的生理适应可能是造成差异的原因。优选的温度分别在23.0-24.0℃和21.5-24.0℃的范围内。在两次调查中,首选湿度分别为47.7%和40.5%。人们通常在加热之前就感到寒冷,而在空间加热期间,在相同温度范围内他们会感到舒适。当相对湿度低于30%时,人们通常会在加热过程中感到干燥,而在加热之前,在相同的相对湿度下,他们会感到舒适。

著录项

  • 来源
    《Building and Environment》 |2011年第11期|p.2170-2178|共9页
  • 作者单位

    School of Municipal & Environmental Engineering, Harbin Institute of Technology, Harbin, Heilongjiang 150090, China;

    School of Municipal & Environmental Engineering, Harbin Institute of Technology, Harbin, Heilongjiang 150090, China;

    School of Municipal & Environmental Engineering, Harbin Institute of Technology, Harbin, Heilongjiang 150090, China;

    School of Municipal & Environmental Engineering, Harbin Institute of Technology, Harbin, Heilongjiang 150090, China;

    School of Municipal & Environmental Engineering, Harbin Institute of Technology, Harbin, Heilongjiang 150090, China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    thermal comfort; residential building; space heating; expectation; severe cold area; field study;

    机译:热舒适性;住宅建筑;空间供暖;预期;严寒地区;实地研究;