首页> 外文期刊>Building and Environment >Water penetration resistance of residential window and wall systems subjected to steady and unsteady wind loading
【24h】

Water penetration resistance of residential window and wall systems subjected to steady and unsteady wind loading

机译:稳定和不稳定风荷载下住宅窗户和墙壁系统的耐水渗透性

获取原文
获取原文并翻译 | 示例
       

摘要

This paper presents results from two interrelated studies that investigated the performance of residential window and wall systems subjected to (1) simplified load scenarios and (2) realistic, time-varying load conditions. The first project investigated the diagnostic ability of standard water penetration test methods for the evaluation of residential systems. Static and rapidly pulsed pressure test protocols were compared using 2.4 m x 2.4 m wall sections with integrated windows. The second project quantified water ingress rates of operable, sliding seal windows under time-varying wind loads derived from wind tunnel measurements. The findings of this research indicated that the application of a static air pressure differential across the specimen is a practical, effective technique to evaluate watertightness of residential windows, however enhancements to the testing approach are warranted if systems level performance is to be evaluated.
机译:本文介绍了两项相互关联的研究的结果,这些研究调查了住宅窗户和墙壁系统在(1)简化的载荷情况和(2)现实的,随时间变化的载荷条件下的性能。第一个项目调查了标准水渗透测试方法对住宅系统评估的诊断能力。使用带有集成窗口的2.4 m x 2.4 m壁部分比较了静态和快速脉冲压力测试方案。第二个项目量化了在风洞测量得出的随时间变化的风荷载下可操作的滑动密封窗的进水率。这项研究的结果表明,在整个样本上施加静态气压差是一种实用,有效的技术,用于评估住宅窗户的水密性,但是,如果要评估系统级性能,则有必要对测试方法进行增强。