首页> 外文期刊>Building and Environment >Experimental assessment of thermal inertia in insulated and non-insulated old limestone buildings
【24h】

Experimental assessment of thermal inertia in insulated and non-insulated old limestone buildings

机译:隔热和非隔热旧石灰石建筑的热惯性实验评估

获取原文
获取原文并翻译 | 示例
       

摘要

The aim of this paper is to evaluate summer thermal inertia in high porosity limestone old buildings. These buildings have to be retrofitted to save energy. Consequently, this paper focuses on the effects of insulation on this property. Monitoring surveys were carried out in an experimental room and in five single-family houses. In summer, thermal inertia may vary in a same building according to the localization of the room and the insulation. The analysis of monitoring data before and after insulation of the experimental room allows to highlight the improvement of thermal inertia of the room thanks to insulation: the decrement factor is divided by 10 and the time lag increases by 4 h. These results are confirmed by single-family houses measurements. The decrement factors of insulated limestone rooms are lower (0.10) than non-insulated ones (0.17) and the time lag increases by 3 h with insulation. Insulation of Tuffeau stone rooms does not cause overheating conditions in summer. These results indicate the benefit of insulation on this passive design. For these buildings, insulation reduces the temperature amplitude in summer and delays the maximum of temperature during the night.
机译:本文的目的是评估高孔隙度石灰石老建筑的夏季热惯性。这些建筑物必须进行翻新以节省能源。因此,本文着重于绝缘对这一特性的影响。监测调查是在一个实验室和五个单户住宅中进行的。在夏季,同一房间内的热惯性可能会因房间和隔热材料的位置而异。对实验室隔热前后的监测数据进行分析可以突出显示由于隔热而带来的房间热惯性的改善:递减系数除以10,时滞增加4 h。这些结果通过单户住宅测量得到证实。绝热石灰岩房间的减量因子(0.10)低于非绝热石灰石房间的减量因子(0.17),保温时间滞后时间增加3小时。 Tuffeau石材房间的隔热不会在夏天引起过热。这些结果表明绝缘对这种无源设计的好处。对于这些建筑物,隔热层可降低夏季的温度幅度,并延迟夜间的最高温度。

著录项

  • 来源
    《Building and Environment》 |2014年第10期|241-248|共8页
  • 作者单位

    CEREMA - DterOuest - DLRCA, 23 avenue de l'Amiral Chauvin, 49136 Les Ponts-de-ce, France,ENTPE - LGCB, Universite de Lyon, Rue Maurice Auain, 69518 Vaulx-en-Velin, France;

    ENTPE - LGCB, Universite de Lyon, Rue Maurice Auain, 69518 Vaulx-en-Velin, France;

    CEREMA - DterOuest - DLRCA, 23 avenue de l'Amiral Chauvin, 49136 Les Ponts-de-ce, France;

    CEREMA - DterOuest - DVT, Rue Rene Viviani BP 46223, 44262 Nantes, France;

    ENTPE - LGCB, Universite de Lyon, Rue Maurice Auain, 69518 Vaulx-en-Velin, France;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Old limestone buildings; Thermal inertia; Insulation; Monitoring survey;