摘要

We report a comprehensive assessment of PM concentrations and its variations in multifamily apartment buildings. Fifty apartments in ten multifamily buildings were investigated during heating seasons of 2011 and 2012 in Kaunas city, Lithuania. PM concentration and size distribution measurements were performed using the optical particle counters indoors and outdoors. Usually mean 24-h indoor PM concentrations were lower (median 7.8 μg/m~3 for PM_(2.5)) than outdoor concentrations (median 16.9 ug/m~3 for PM_(2.5)) of corresponding location, and I/O ratios of PM_(2.5) were lower (0.70) than that of PM_(10) (0.98). Night time levels, representing background indoor exposure to PM, were equal to 5.0 (PM_(2.5)) and 6.7 μg/ m~3 (PM_(10)), respectively. Particle deposition rates were determined by regression fitting of the measured PM_2.5 concentration decay curves, with the median equal to 0.32 h~(-1). The data have been discussed aiming to characterize indoor PM sources and select the most representative indicator(s) for an assessment of the effects of energy saving refurbishment on indoor air quality. We found that a combination of several indicators allowed an adequate characterization of indoor PM sources and can be used in the subsequent assessment.
机译:我们报告了对多户公寓楼中PM浓度及其变化的综合评估。在2011年和2012年供暖季节期间,对立陶宛考纳斯市十栋多户住宅中的50套公寓进行了调查。使用室内和室外的光学粒子计数器进行PM浓度和尺寸分布测量。通常,平均24小时室内PM浓度(PM_(2.5)的中位数为7.8μg/ m〜3)要低于相应位置的室外浓度(PM_(2.5)的中位数为16.9 ug / m〜3)和I / O比PM_(2.5)的比例低于(0.70)PM_(10)(0.98)。代表室内室内暴露于PM的夜间水平分别等于5.0(PM_(2.5))和6.7μg/ m〜3(PM_(10))。通过对测得的PM_2.5浓度衰减曲线进行回归拟合确定颗粒沉积速率,中值等于0.32 h〜(-1)。讨论了这些数据,旨在表征室内PM源并选择最具代表性的指标来评估节能翻新对室内空气质量的影响。我们发现,几种指标的组合可以对室内PM源进行充分表征,并可以用于后续评估中。

著录项

  • 来源
    《Building and Environment》 |2014年第6期|10-17|共8页
  • 作者单位

    Department of Environmental Technology, Kaunas University of Technology, Radvitenu pl. 19,LT50254 Kaunas, Lithuania;

    Department of Environmental Technology, Kaunas University of Technology, Radvitenu pl. 19,LT50254 Kaunas, Lithuania;

    Department of Environmental Technology, Kaunas University of Technology, Radvitenu pl. 19,LT50254 Kaunas, Lithuania;

    Department of Environmental Technology, Kaunas University of Technology, Radvitenu pl. 19,LT50254 Kaunas, Lithuania;

    Department of Environmental Technology, Kaunas University of Technology, Radvitenu pl. 19,LT50254 Kaunas, Lithuania;

    Department of Environmental Technology, Kaunas University of Technology, Radvitenu pl. 19,LT50254 Kaunas, Lithuania;

    Department of Environmental Technology, Kaunas University of Technology, Radvitenu pl. 19,LT50254 Kaunas, Lithuania;

    Department of Building Energy Systems, Kaunas University of Technology, Radvilenu pl. 19, LTS0254 Kaunas, Lithuania;

    Department of Building Energy Systems, Kaunas University of Technology, Radvilenu pl. 19, LTS0254 Kaunas, Lithuania;

    Department of Environmental Health, National Institute for Health and Welfare, Neulaniementie 4, Kuopio FI-70701, Finland;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Indoor air quality; Particulate matter; Indoor/outdoor concentrations; Multifamily buildings; Building refurbishment; Spatial and temporal variability;

    机译:室内空气质量颗粒物;室内/室外浓度;多户住宅;建筑翻新;时空变异;