首页> 外文期刊>Building acoustics >Retrofitting masonry and cavity brick facades for different noise zones using laboratory measurements
【24h】

Retrofitting masonry and cavity brick facades for different noise zones using laboratory measurements

机译:使用实验室测量值对不同噪声区域的砖石和空心砖外墙进行改造

获取原文
获取原文并翻译 | 示例
           

摘要

Facade airborne sound insulation is crucial for protection of indoor environment from environmental noise. In Turkey, sound insulation in new buildings is bound by law, but 6 million pre-1980 dwellings with thin brick walls and single-glazed windows used in highly transparent facades should be retrofitted. In this study, sound reduction index of masonry and cavity exterior walls which consist of brick, mortar, gypsum board and mineral wool and of common window types is measured in sound insulation test rooms. The study compares and evaluates the effects of plaster, brick thickness, cavity depth, mineral wool thickness and mineral wool placement on sound reduction index values, using traditional materials and building techniques. Traditional brick wall facades and possible retrofitting of these facades are evaluated for sound insulation of bedrooms and living rooms in different noise zones, 55, 60, 65, 70 and 75dBA, with various transparency ratios, 0%, 30%, 40%, 50% and 70%. The analysis shows that window types and single-layer walls are the deterministic factors in evaluating sound insulation in retrofitting projects and that it is not possible to provide proper aural comfort in high noise zones.
机译:外墙空气传播的隔声对于保护室内环境免受环境噪声的影响至关重要。在土耳其,新建筑物的隔音是受法律约束的,但是,在1980年前的600万所房屋中,应使用薄砖墙和用于高度透明外墙的单层玻璃窗进行改造。在这项研究中,在隔音测试室中测量了由砖,砂浆,石膏板和矿棉组成的砖石和型腔外墙的隔音系数,以及常见的窗户类型。该研究使用传统材料和建筑技术比较并评估了石膏,砖厚,型腔深度,矿棉厚度和矿棉放置对降噪指数值的影响。对传统砖墙外墙和这些外墙的可能翻新进行了评估,以评估卧室和客厅在55、60、65、70和75dBA不同噪声区域的隔音效果,并具有各种透明度比率,分别为0%,30%,40%,50 %和70%。分析表明,窗户类型和单层墙是评估改造项目隔音效果的确定性因素,并且在高噪声区域无法提供适当的听觉舒适性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号