There are concerns about workers repeatedly exposed to magnetic fields exceeding regulatory limits with respect to modern magnetic resonance imaging (MRI). As a result, there is need for an ambulatory magnetic field dosimeter capable of measuring these fields in and around an MRI scanner in order to evaluate the regulatory guidelines and determine any underlying exposure risks. This study presents results of tri-axial measurements using an ambulatory magnetic field dosimeter worn by workers during normal working shifts. We recorded and analyzed magnetic field exposures in and around 1.5 T, 2 T, and 4 T magnets during routine patient procedures. The data was integrated and averaged over time and evaluated against the latest exposure standards. Time-varying magnetic fields occur when individuals move through spatially non-uniform static magnetic fields or during gradient-pulsed magnetic fields or a combination of both. Our previous numerical analysis shows that at certain positions surrounding the MRI scanner ends, such fields may induce current densities and electric fields that may exceed the relevant EU, ICNIRP, and IEEE standards. A high-speed acquisition version of the dosimeter measured gradient-pulsed fields at positions accessible by MRI workers near the scanner ends, and the results were evaluated and compared against the numerical simulations and the standards. Our measurements confirm that workers can be exposed to magnetic fields exceeding the guidelines at positions near the gradient coil ends during clinical imaging and a high degree of correlation exists with the numerical results. While the time-weighted average magnetic field exposures in 1.5 T, 2 T, and 4 T were all within the regulatory limits during static magnetic field measurements, the peak limits for the head can be exceeded in some circumstances. This study presents a small number of routine shifts of data that provide indicative results of magnetic field exposure in real situations.
机译:对于现代磁共振成像(MRI),人们担心工人反复暴露于超出监管限制的磁场中。因此,需要一种能够测量MRI扫描仪内部和周围的这些磁场的动态磁场剂量计,以便评估监管指南并确定任何潜在的暴露风险。这项研究提出了使用正常工作班次工人佩戴的动态磁场剂量计进行三轴测量的结果。我们记录并分析了常规患者手术过程中1.5 T,2 T和4 T磁体及其附近的磁场暴露。对数据进行积分并随时间平均,然后根据最新的暴露标准进行评估。当个体在空间上不均匀的静态磁场中移动或在梯度脉冲磁场或两者结合时会发生时变磁场。我们之前的数值分析表明,在MRI扫描仪末端周围的某些位置,此类磁场可能会感应出可能超过相关EU,ICNIRP和IEEE标准的电流密度和电场。剂量计的高速采集版本在靠近扫描仪末端的MRI工作人员可及的位置测量了梯度脉冲场,并对结果进行了评估并与数值模拟和标准进行了比较。我们的测量结果证实,在临床成像过程中,工作人员可能会在梯度线圈末端附近的位置暴露于超出规定范围的磁场,并且与数值结果高度相关。虽然在静态磁场测量期间,在1.5 T,2 T和4 T中的时间加权平均磁场暴露量均在监管限制之内,但在某些情况下可能会超出磁头的峰值限制。这项研究提出了少量的例行数据移位,这些移位提供了真实情况下磁场暴露的指示性结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号