The objectives of this paper are to propose a method that can accurately estimate the human heart rate (HR) using an ultrawideband (UWB) radar system, and to determine the performance of the proposed method through measurements. The proposed method uses the feature points of a radar signal to estimate the HR efficiently and accurately. Fourier- and periodicity-based methods are inappropriate for estimation of instantaneous HRs in real time because heartbeat waveforms are highly variable, even within the beat-to-beat interval. We define six radar waveform features that enable correlation processing to be performed quickly and accurately. In addition, we propose a feature topology signal that is generated from a feature sequence without using amplitude information. This feature topology signal is used to find unreliable feature points, and thus, to suppress inaccurate HR estimates. Measurements were taken using UWB radar, while simultaneously performing electrocardiography measurements in an experiment that was conducted on nine participants. The proposed method achieved an average root-mean-square error in the interbeat interval of 7.17 ms for the nine participants. The results demonstrate the effectiveness and accuracy of the proposed method. The significance of this study for biomedical research is that the proposed method will be useful in the realization of a remote vital signs monitoring system that enables accurate estimation of HR variability, which has been used in various clinical settings for the treatment of conditions such as diabetes and arterial hypertension.
机译:本文的目的是提出一种可以使用超宽带(UWB)雷达系统准确估算人心率(HR)的方法,并通过测量确定该方法的性能。所提出的方法利用雷达信号的特征点来有效,准确地估计心率。基于心跳和周期性的方法不适合实时估算瞬时HR,因为即使在心跳间隔内,心跳波形也是高度可变的。我们定义了六个雷达波形特征,这些特征使快速,准确地执行相关处理成为可能。另外,我们提出了一种从特征序列生成的特征拓扑信号,而无需使用幅度信息。该特征拓扑信号用于查找不可靠的特征点,从而抑制不准确的HR估计。使用UWB雷达进行测量,同时在针对9位参与者的实验中同时执行心电图测量。所提出的方法在九个参与者的心跳间隔中的平均均方根误差为7.17 ms。结果证明了该方法的有效性和准确性。这项研究对生物医学研究的意义在于,提出的方法将对实现远程生命体征监测系统非常有用,该系统能够准确估算HR变异性,该系统已在各种临床环境中用于治疗糖尿病等疾病和动脉高血压。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号