Intraocular pressure (IOP) is the leading modifiable risk factor for preventing vision loss in glaucoma patients. Direct and frequent IOP measurements are highly desirable to assess adequacy of treatment and prevent further vision loss. In this study, we report on successful in vivo measurements of intraocular pressure in rabbits using an optical IOP measurement system. The sensor was implanted during cataract surgery in two New Zealand white (NZW) rabbits and tested in vivo for ten weeks. Prior to implantation, the sensors were characterized in vitro in the physiologically relevant pressure range of 0-60 mmHg. A portable wireless handheld reader consisting of an internal beam splitter, a monochromatic light source, and a digital single-lens reflex (DSLR) camera was also designed and implemented to capture interference patterns from the sensor. The sensitivity and accuracy of the sensor was 30 nm/mmHg and +/- 0.2 mmHg, respectively. Ten weeks post-implantation, the two NZW rabbits continued to respond well to the implant with no observable inflammation, signs of infection, or biofouling. All IOP measurements were obtained using the portable DSLR handheld reader. Successful in vivo studies demonstrate biocompatibility of the IOP sensor and prove feasibility of the IOP measurement system. The system has the potential to be used in both clinical and patient point-of-care (home) settings to frequently and accurately measure pressure.
机译:眼内压(IOP)是预防青光眼患者视力丧失的主要可改变的危险因素。直接和频繁的IOP测量非常希望评估治疗的充分性并防止进一步的视力丧失。在这项研究中,我们使用光学IOP测量系统在兔子中的体内压力方面的成功进行报告。在两只新西兰白(NZW)兔子的白内障手术期间植入传感器,并在体内进行了十个星期。在植入之前,在0-60mmHg的生理相关压力范围内体外表征传感器。还设计并实现了由内部分束器,单色光源和数字单镜头反射(DSLR)相机组成的便携式无线手持式读取器,以捕获来自传感器的干扰图案。传感器的灵敏度和精度分别为30nm / mmHg和+/- 0.2mmHg。植入后十周,两只NZW兔继续良好对植入物响应,没有可观察到的炎症,感染症或生物污染。使用便携式DSLR手持读取器获得所有IOP测量。体内研究成功证明了IOP传感器的生物相容性,并证明了IOP测量系统的可行性。该系统具有在临床和患者的护理点(家庭)设置中使用的可能性,以经常和准确地测量压力。

著录项

  • 来源
    《IEEE Transactions on Biomedical Engineering》 |2020年第3期|931-937|共7页
  • 作者单位

    Univ Calif San Diego Dept Mech & Aerosp Engn La Jolla CA 92093 USA|Univ Calif San Diego Ctr Memory & Recording Res La Jolla CA 92093 USA;

    Univ Calif San Diego Dept Mech & Aerosp Engn La Jolla CA 92093 USA|Univ Calif San Diego Ctr Memory & Recording Res La Jolla CA 92093 USA;

    Univ Calif San Diego Hamilton Glaucoma Ctr Shiley Eye Inst La Jolla CA 92093 USA|Univ Calif San Diego Dept Ophthalmol Viterbi Family La Jolla CA 92093 USA;

    Univ Calif San Diego Dept Mech & Aerosp Engn La Jolla CA 92093 USA|Univ Calif San Diego Ctr Memory & Recording Res La Jolla CA 92093 USA;

    Univ Calif San Diego Dept Mech & Aerosp Engn La Jolla CA 92093 USA|Univ Calif San Diego Ctr Memory & Recording Res La Jolla CA 92093 USA;

    Univ Calif San Diego Hamilton Glaucoma Ctr Shiley Eye Inst La Jolla CA 92093 USA|Univ Calif San Diego Dept Ophthalmol Viterbi Family La Jolla CA 92093 USA;

    Univ Calif San Diego Dept Mech & Aerosp Engn La Jolla CA 92093 USA|Univ Calif San Diego Ctr Memory & Recording Res La Jolla CA 92093 USA;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Intraocular pressure sensor; reader; pressure; measurement system; interferometry; glaucoma;