In recent years, many efforts have been made to promote a healthcare paradigm shift from the traditional reactive hospital-centered healthcare approach towards a proactive, patient-oriented, and self-managed approach that could improve service quality and help reduce costs while contributing to sustainability. Managing and caring for patients with chronic diseases accounts over 75% of healthcare costs in developed countries. One of the most resource demanding diseases is chronic kidney disease (CKD), which often leads to a gradual and irreparable loss of renal function, with up to 12% of the population showing signs of different stages of this disease. Peritoneal dialysis and home haemodialysis are life-saving home-based renal replacement treatments that, compared to conventional in-center hemodialysis, provide similar long-term patient survival, less restrictions of life-style, such as a more flexible diet, and better flexibility in terms of treatment options and locations. Bioimpedance has been largely used clinically for decades in nutrition for assessing body fluid distributions. Moreover, bioimpedance methods are used to assess the overhydratation state of CKD patients, allowing clinicians to estimate the amount of fluid that should be removed by ultrafiltration. In this work, the initial validation of a handheld bioimpedance system for the assessment of body fluid status that could be used to assist the patient in home-based CKD treatments is presented. The body fluid monitoring system comprises a custom-made handheld tetrapolar bioimpedance spectrometer and a textile-based electrode garment for total body fluid assessment. The system performance was evaluated against the same measurements acquired using a commercial bioimpedance spectrometer for medical use on several voluntary subjects. The analysis of the measurement results and the comparison of the fluid estimations indicated that both devices are equivalent from a measurement performance perspective, allowing for its use on ubiquitous e-healthcare dialysis solutions.
机译:近年来,人们为推动医疗模式从传统的以医院为中心的反应型医疗方法向主动,以患者为中心和自我管理的方法转变做出了许多努力,以改善服务质量并降低成本,同时促进可持续发展。在发达国家,管理和照顾慢性病患者占医疗费用的75%以上。对资源最苛刻的疾病之一是慢性肾脏病(CKD),它通常会导致逐渐且无法弥补的肾功能丧失,多达12%的人口显示出该疾病不同阶段的征兆。腹膜透析和家庭血液透析是可挽救生命的家庭肾脏替代治疗,与传统的中心血液透析相比,可提供相似的长期患者存活率,更少的生活方式限制,例如更灵活的饮食和更好的灵活性就治疗方案和位置而言。数十年来,生物阻抗已在临床上广泛用于营养中以评估体液分布。此外,生物阻抗方法用于评估CKD患者的过度水化状态,从而使临床医生能够估计应通过超滤去除的体液量。在这项工作中,提出了用于评估体液状态的手持式生物阻抗系统的初步验证,该系统可用于协助患者在家中进行CKD治疗。体液监测系统包括定制的手持式四极生物阻抗谱仪和用于全身液评估的基于纺织品的电极衣。系统性能是通过使用商用生物阻抗谱仪在几个自愿受试者上使用的医学生物阻抗光谱仪获得的相同测量结果进行评估的。对测量结果的分析和对流体估计值的比较表明,从测量性能的角度来看,这两种设备是等效的,从而使其可用于无处不在的电子医疗透析解决方案。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号