...
首页> 外文期刊>Biological Cybernetics >Using individual-muscle specific instead of across-muscle mean data halves muscle simulation error
【24h】

Using individual-muscle specific instead of across-muscle mean data halves muscle simulation error

机译:使用特定于个别肌肉而非跨肌肉的均值数据可将肌肉模拟误差减半

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Hill-type parameter values measured in experiments on single muscles show large across-muscle variation. Using individual-muscle specific values instead of the more standard approach of across-muscle means might therefore improve muscle model performance. We show here that using mean values increased simulation normalized RMS error in all tested motor nerve stimulation paradigms in both isotonic and isometric conditions, doubling mean simulation error from 9 to 18 (different at p 0.0001). These data suggest muscle-specific measurement of Hill-type model parameters is necessary in work requiring highly accurate muscle model construction. Maximum muscle force (F max) showed large (fourfold) across-muscle variation. To test the role of F max in model performance we compared the errors of models using mean F max and muscle-specific values for the other model parameters, and models using muscle-specific F max values and mean values for the other model parameters. Using muscle-specific F max values did not improve model performance compared to using mean values for all parameters, but using muscle-specific values for all parameters but F max did (to an error of 14, different from muscle-specific, mean all parameters, and mean only F max errors at p ≤ 0.014). Significantly improving model performance thus required muscle-specific values for at least a subset of parameters other than F max, and best performance required muscle-specific values for this subset and F max. Detailed consideration of model performance suggested that remaining model error likely stemmed from activation of both fast and slow motor neurons in our experiments and inadequate specification of model activation dynamics.
机译:在单块肌肉的实验中测量的Hill型参数值显示出较大的跨肌肉变化。因此,使用单个肌肉特定值而不是跨肌肉均等的更标准方法可能会改善肌肉模型的性能。我们在这里显示,在等张和等轴测条件下,所有测试的运动神经刺激范例中使用平均值增加的模拟归一化RMS误差,将平均模拟误差从9倍增加到18(在p <0.0001处不同)。这些数据表明,在需要高度精确的肌肉模型构建的工作中,必须对Hill型模型参数进行特定于肌肉的测量。最大肌肉力量(F max )表现出较大的(四倍)跨肌肉变化。为了测试F max 在模型性能中的作用,我们比较了使用平均F max 和其他模型参数的肌肉特定值的模型以及使用肌肉特定F max 的模型的误差。 >其他模型参数的值和平均值。与使用所有参数的平均值相比,使用特定于肌肉的F max 值并不能改善模型性能,但是对除F max 以外的所有参数使用特定于肌肉的值(误差为14,不同从肌肉特异性出发,均指所有参数,且均仅在p≤0.014时表示F max 误差)。因此,要显着改善模型性能,至少需要除F max 以外的参数子集的肌肉特定值,而对于最佳性能,需要对该子集和Fmax 的肌肉特定值。对模型性能的详细考虑表明,剩余的模型错误可能源于我们实验中快速和慢速运动神经元的激活以及模型激活动力学的规范不足。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号