首页> 外文期刊>Atomic Energy >UPGRADING OF A RELIABLE WATER SUPPLY SYSTEM AT THE KOLA NUCLEAR POWER PLANT FOR SERVICE LIFE EXTENSION
【24h】

UPGRADING OF A RELIABLE WATER SUPPLY SYSTEM AT THE KOLA NUCLEAR POWER PLANT FOR SERVICE LIFE EXTENSION

机译:KOLA核电厂延长使用寿命的可靠供水系统的升级

获取原文
获取原文并翻译 | 示例
           

摘要

Measures taken to develop and put into operation three new exterior channels for emergency process water with two additional 60VTs pumping units, which remain operational even during an earthquake and were installed in the second block pumping station, are described. In addition, the three existing 12NDS horizontal pumping units were used as a basis to develop a third channel for the emergency process water. Above-ground water ducts with thermal insulation and heating systems to prevent freezing during the anticipation state, which is the constant state of the emergency system, were laid. As a result of upgrading with the development of three channels, the emergency process water feeding reached an adequately safe level of reliability.
机译:描述了为开发用于紧急过程用水的三个新外部通道并使用两个额外的60VT抽水单元而采取的措施,这些抽水单元即使在地震中也保持运转,并安装在第二个抽水站中。此外,现有的三个12NDS卧式抽水机被用作开发应急处理水的第三条通道的基础。铺设了具有隔热和加热系统的地上水管道,以防止在紧急状态(即紧急状态的恒定状态)期间冻结。随着三个渠道的发展升级,紧急过程给水达到了足够安全的可靠性水平。

著录项

  • 来源
    《Atomic Energy》 |2006年第3期|p.172-175|共4页
  • 作者单位

    SPbAtomenergoproekt;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 原子能技术;
  • 关键词