首页> 外文期刊>Atmospheric environment >Field evaluation of two diffusive samplers and two adsorbent media to determine 1,3-butadiene and benzene levels in air
【24h】

Field evaluation of two diffusive samplers and two adsorbent media to determine 1,3-butadiene and benzene levels in air

机译:现场评估两个扩散采样器和两种吸附剂介质,以确定空气中的1,3-丁二烯和苯水平

获取原文
获取原文并翻译 | 示例
           

摘要

Two types of diffusive samplers, both of which are compatible with thermal desorption, but differ in their geometry— SKC-Ultra (badge-type) and Radiello (radial symmetry-type)—were evaluated indoors and outdoors under varying temperature, humidity and wind speed conditions, using the graphitized adsorbents Carbopack X or Carbograph 5 to measure 1,3-butadiene and benzene in ambient air. The results obtained by diffusive sampling were compared with results obtained using a conventional active sampling method over both long (1 week) and shorter periods (6-24 h). Analysis and detection were performed using an automatic thermal desorber (ATD) connected to a gas chromatograph-flame ionization detector (GC/FID). Results from each sampler and adsorbent combination were examined using ordinary or multiple linear regression analysis. The overall uncertainty (OU) was also determined. In general, the results obtained with both samplers showed good agreement with those obtained by active sampling. Carbopack X appeared to be a more efficient adsorbent than Carbograph 5 for 1,3-butadiene, but the two adsorbents were equivalent for benzene. No effects of either humidity or air velocity were observed. Minor temperature effects were observed for both samplers for 1,3-butadiene. In summary, the results confirmed the accuracy of sampling rates previously determined for the two samplers and adsorbents. We consider the two samplers to be suitable for stationary and personal monitoring for the general population of 1,3-butadiene and benzene in various environments, indoors and outdoors. They are almost independent of meteorological conditions and may be suitable for monitoring industrial atmospheres.
机译:两种扩散采样器均与热脱附兼容,但它们的几何形状不同-SKC-Ultra(徽章型)和Radiello(径向对称型)在不同温度,湿度和风下在室内和室外进行了评估在高速条件下,使用石墨化吸附剂Carbopack X或Carbograph 5测量环境空气中的1,3-丁二烯和苯。将通过扩散采样获得的结果与使用常规主动采样方法在较长时间(1周)和较短时间段(6-24小时)中获得的结果进行比较。使用连接到气相色谱-火焰电离检测器(GC / FID)的自动热脱附器(ATD)进行分析和检测。使用常规或多元线性回归分析检查每个采样器和吸附剂组合的结果。还确定了总体不确定度(OU)。通常,两个采样器获得的结果都与主动采样获得的结果一致。对于1,3-丁二烯,Carbopack X似乎是比Carbograph 5更有效的吸附剂,但两种吸附剂对苯是等效的。没有观察到湿度或空气速度的影响。两种样品的1,3-丁二烯均观察到较小的温度影响。总而言之,结果证实了先前为两种采样器和吸附剂确定的采样率的准确性。我们认为这两个采样器适合在室内和室外的各种环境中对1,3-丁二烯和苯的一般人口进行固定和个人监测。它们几乎与气象条件无关,并且可能适合于监视工业大气。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号