首页> 外文期刊>Atmospheric environment >Performance evaluation of modified Semi-continuous Elements in Aerosol Sampler-Ill
【24h】

Performance evaluation of modified Semi-continuous Elements in Aerosol Sampler-Ill

机译:改进的半连续元素在气溶胶采样器中的性能评估

获取原文
获取原文并翻译 | 示例
           

摘要

A field study was conducted to evaluate the performance of a Semi-continuous Elements in Aerosol Sampler-Ill (SEAS-Ⅲ), designed to collect ambient PM2.5 aerosol samples at a time resolution of 30 min for elemental concentration measurements. Two identical but modified SEAS-III samplers were operated for four continuous weeks in Dearborn, Ml, during July-August 2007. A total of 2308 samples were collected from the two samplers. Sampling completeness from the primary and duplicate samplers was 90% and 84%, respectively. All of the collected samples were analyzed for dilute acid-extractable trace metal concentrations using HR-ICPMS. A total of 878 collection time-matched sample pairs were available to evaluate whole-system uncertainty from collocated concentration measurements. The collocated precision for the 27 studied elements (Al, As, Ba, Ca, Cd, Ce, Cs, Cu, Fe, Ge, K, La, Mg, Mn, Mo, Na, P, Pb, Rb, S, Sb, Se, Sn, Sr, Ti, V, and Zn) varied between 9% and 40%. Twenty elements showed precision better than 25%. Uncertainty estimates from propagation of errors compared well with the whole-system uncertainty values for all minor aerosol elements studied. SEAS-III measurements of As, Cd, Ge, K, La, Mn, Mo, Na, Rb, Se, Sb, Sr, Ti, V, and Zn correlated well (r > 0.8) with a FRM equivalent PM2.5 integrated filter sampling method. Based on these measurements, collection efficiency of SEAS-Ⅲ was estimated to be 87±16%. Solubility of particles in the collection medium (water) was identified as a possible reason for low recovery of Al, Fe, Pb, Sb, and Sn.
机译:进行了现场研究,以评估半连续元素在气溶胶采样器-III(SEAS-Ⅲ)中的性能,该半连续元素旨在以30分钟的时间分辨率收集环境PM2.5气溶胶样品以进行元素浓度测量。在2007年7月至8月期间,在密歇根州迪尔伯恩连续运行了两个相同但经过改进的SEAS-III采样器,连续进行了四个星期。从两个采样器中总共收集了2308个样品。一级和二级采样器的采样完整性分别为90%和84%。使用HR-ICPMS分析所有收集的样品的稀酸可萃取痕量金属浓度。共有878个采集时间匹配的样品对可用于通过并置浓度测量评估整个系统的不确定性。 27种研究元素(Al,As,Ba,Ca,Cd,Ce,Cs,Cu,Fe,Ge,K,La,Mg,Mn,Mo,Na,P,Pb,Rb,S,Sb ,Se,Sn,Sr,Ti,V和Zn)在9%至40%之间变化。二十个元素显示的精度优于25%。对于研究的所有次要气溶胶元素,将误差传播的不确定性估计值与整个系统的不确定性值进行了比较。集成了FRM等效PM2.5的As,Cd,Ge,K,La,Mn,Mo,Na,Rb,Se,Sb,Sr,Ti,V和Zn的SEAS-III测量值具有很好的相关性(r> 0.8)过滤器采样方法。基于这些测量,SEAS-Ⅲ的收集效率估计为87±16%。颗粒在收集介质(水)中的溶解度被确定为Al,Fe,Pb,Sb和Sn回收率低的可能原因。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号