首页> 外文期刊>Atmospheric environment >Determination of hexavalent chromium in ambient air: A story of method induced Cr(III) oxidation
【24h】

Determination of hexavalent chromium in ambient air: A story of method induced Cr(III) oxidation

机译:测定环境空气中的六价铬:方法引起的Cr(III)氧化的故事

获取原文
获取原文并翻译 | 示例
           

摘要

The accuracy of the determination of Cr(VI) in ambient paniculate matter remains a challenge from the point of view of minimal Cr species interconversion. Knowledge of this method induced oxidation and reduction is particularly relevant for the determination of Cr(VI) in ambient paniculate matter, as the level of observed Cr(III) oxidation (average of 1.7% in this study) can contribute significantly to the monitored range of measured Cr(VI) in PMio. For Cr concentrations in PMio > 10 ng Cr m"3, this method induced oxidation could lead to false positive exceeding of an air quality guideline value of 0.2 ng Cr(VI) m"3 in PMio. The median daily Cr(VI) concentration in PMio measured over a monitoring period of more than 2 months at two locations close to a stainless steel factory amounted to 0.9 ng Cr(VI) rrr3 and 0.27 ng Cr(VI) m"3. Average daily Cr(VI)/Cr ratios in PMio of 3.5% and 2.6% were measured at these locations. The described monitoring for the determination of Cr(VI) in ambient air via alkaline impregnated filters is sensitive (method detection limit of 0.015 ng Cr(VI) m~3) and reproducible (precision of the method ~25%). The average Cr(VI) recovery of 75% strongly indicates the effects of ambient sampling conditions and ambient particles on the Cr(VI) recoveries. The stability of the Cr(VI) and the Cr(III) spike on 0.12 M NaHCO_3 impregnated filters observed with XANES, indicates that the alkaline extraction of the filter in combination with the sampled air matrix is likely to induce the Cr conversions. The XANES spectra shows further that a Cr-spinel is the predominant component of Cr in ambient air PMio at the monitored locations.
机译:从最小的Cr物种相互转化的角度来看,测定环境中的微粒中Cr(VI)的准确性仍然是一个挑战。该方法诱导的氧化和还原的知识与测定周围颗粒中的Cr(VI)特别相关,因为观察到的Cr(III)氧化水平(本研究中的平均值为1.7%)可以显着影响监测范围PMio中测得的Cr(VI)的平均值。当PMio中的Cr浓度> 10 ng Cr m“ 3时,这种方法引起的氧化可能导致PMio中空气质量指标值误为0.2 ng Cr(VI)m” 3。在超过两个月的监测期内,在靠近一家不锈钢工厂的两个地点测得的PMio中的每日Cr(VI)浓度中值为0.9 ng Cr(VI)rrr3和0.27 ng Cr(VI)m“ 3。平均值每天在这些位置测得的PMio中的Cr(VI)/ Cr比率分别为3.5%和2.6%。所述通过碱浸滤池测定环境空气中Cr(VI)的监测非常灵敏(方法检测极限为0.015 ng Cr (VI)m〜3)和可重复性(该方法的精密度〜25%),平均Cr(VI)回收率达到75%,强烈表明环境采样条件和环境颗粒对Cr(VI)回收率的影响。 XANES观察到的在0.12 M NaHCO_3浸渍的过滤器上的Cr(VI)和Cr(III)峰值的变化表明,碱性过滤器结合采样空气基质的萃取很可能会导致Cr转化。此外,Cr-尖晶石是环境中Cr的主要成分红外PMio在受监视的位置。

著录项

  • 来源
    《Atmospheric environment》 |2011年第30期|p.5332-5341|共10页
  • 作者单位

    Flemish Institute for Technological Research, Boeretang 200, 2400 Mol, Belgium;

    Ghent University, X-ray Microspectroscopy and Imaging Research Croup (XMI), Department of Analytical Chemistry, Ghent University, Krijgslaan 281 S12, B-9000 Gent, Belgium;

    Flemish Institute for Technological Research, Boeretang 200, 2400 Mol, Belgium;

    Flemish Environment Agency, Department Air, Communication and Environment, Section Air, Kronenburgstraat 45, B-2000 Antwerp, Belgium;

    Flemish Environment Agency, Department Air, Communication and Environment, Section Air, Kronenburgstraat 45, B-2000 Antwerp, Belgium;

    Flemish Institute for Technological Research, Boeretang 200, 2400 Mol, Belgium;

    Flemish Institute for Technological Research, Boeretang 200, 2400 Mol, Belgium;

    Ghent University, X-ray Microspectroscopy and Imaging Research Croup (XMI), Department of Analytical Chemistry, Ghent University, Krijgslaan 281 S12, B-9000 Gent, Belgium;

    Flemish Institute for Technological Research, Boeretang 200, 2400 Mol, Belgium;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    hexavalent chromium; trivalent chromium; interconversion; stability; xanes; paniculate matter; monitoring method;

    机译:六价铬三价铬互变稳定性烷类颗粒物监测方法;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号