首页> 外文期刊>Atmospheric environment >Comparative field test for measurement of PM_(10) dust in atmospheric air using gravimetric (reference) method and β-absorption method (Eberline FH 62-1)
【24h】

Comparative field test for measurement of PM_(10) dust in atmospheric air using gravimetric (reference) method and β-absorption method (Eberline FH 62-1)

机译:用重量(参考)法和β吸收法测量大气中PM_(10)灰尘的比较现场测试(Eberline FH 62-1)

获取原文
获取原文并翻译 | 示例
           

摘要

The paper presents the results of a field test carried out in Gdansk region between 01-01-2010 and 31-12-2010 in order to demonstrate equivalence of the Eberline FH 62-1 sampler to the reference gravimetric method of suspended PM_(10) dust measurement. The differences in PM_(10) dust concentration provided by both methods have been discussed for different seasons of the year. A method of estimation of the correction factors/correction equations has been described based on the European Union guide "Demonstration of Equivalence of Ambient Air Monitoring Methods. EC Working Group on Guidance for the Demonstration of Equivalence". The results obtained from Eberline sampler are equivalent to the ones from gravimetric method, but after application of data correction. The investigation revealed different correction factors/correction equations for winter and summer season. The winter season is characterized by higher PM_(10) concentration and bigger discrepancies between both methods. A lack of equivalence has been found for PM_(10) dust concentration higher than 30 μg m~(-3).
机译:本文介绍了在2010年1月1日至2010年12月31日在格但斯克地区进行的现场测试的结果,目的是证明Eberline FH 62-1采样器与悬浮PM_(10)的参考重量法等效灰尘测量。讨论了一年中不同季节两种方法提供的PM_(10)尘埃浓度的差异。根据欧盟指南“环境空气监测方法的等效性演示。EC等效性指导指南工作组”,介绍了一种估算校正因子/校正方程的方法。从Eberline采样器获得的结果与通过重量分析法获得的结果相同,但经过数据校正之后。调查揭示了冬季和夏季的不同校正因子/校正方程式。冬季的特点是PM_(10)浓度较高,两种方法之间的差异较大。已发现PM_(10)尘埃浓度高于30μgm〜(-3)时缺乏等效性。

著录项

  • 来源
    《Atmospheric environment》 |2012年第7期|p.18-24|共7页
  • 作者

    J. Gebicki; K. Szymariska;

  • 作者单位

    Department of Chemical and Process Engineering, Chemical Faculty, Gdansk University of Technology, Narutowicza Str. 11/12, 80-233 Gdansk, Poland;

    Agency of Regional Air Quality Monitoring in the Gdansk Metropolitan Area (ARMAAG), Brzozowa Str. 15A, 80-243 Gdansk, Poland;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    PM_(10) dust; field test; correction factors; eberline sampler;

    机译:PM_(10)灰尘;现场试验;校正因子;艾伯琳采样器;