Increased thermal performance of metal building roof and wall assemblies can be achieved by using double layers of fiberglass batt insulation. Determination of the installed double layer assembly U-factor is more complex than that of a single layer assembly when each layer has different material properties. Experimental data on the compression of typical fiberglass batt insulation samples are presented along with the derivation of the double layer U-factor equations. Finally, an example is presented to illustrate the application of the U-factor equations. These equations comprise the basis for the revised double layer U-factors for ASHRAE Standard 90.1-2010.
机译:通过使用双层玻璃纤维棉毡隔热层,可以提高金属建筑物屋顶和墙壁组件的热性能。当每一层具有不同的材料特性时,确定已安装的双层组件的U因子比单层组件的U因子更复杂。给出了有关典型玻璃纤维棉胎隔热样品压缩的实验数据以及双层U因子方程的推导。最后,给出一个例子来说明U因子方程的应用。这些公式构成了ASHRAE标准90.1-2010修订的双层U因子的基础。

著录项

  • 来源
    《ASHRAE Transactions》 |2010年第1期|P.177-188|共12页
  • 作者单位

    Center of Science and Technology, Owens Corning, Granville, OH;