Navigating ASHRAE STANDARD 90.1 - 2010 Requirements for Economizers in Datacom

机译:浏览ASHRAE STANDARD 90.1-2010数据通信中节能器的要求

获取原文
获取原文并翻译 | 示例
           

摘要

ANSI/ASHRAE/IESNA Standard-90.1, Energy Standard for Buildings Except Low-Rise Residential Buildings, has been amended by the Standing Standard Project Committee (SSPC) to include data centers within the scope of the 2010 edition following approval of Addenda AQ. Addenda BU was also approved, which establishes some specific criteria for data centers, including some key exemptions for economizers. As a result, any jurisdictions that adopt the 2010 edition of Standard-90.1 for their energy code compliance will result in a substantial change for the "Datacom " industry. Prior to this change, the Datacom industry was left to its own devices and discretion on energy efficiency strategies, which has been gaining significant momentum in recent years resulting in rapid and noteworthy innovation on the energy efficiency front (Google blog, 2010). The changes introduced within 90.1 raise concern over the possible squelching of innovation brought about by prescriptive based industry standards. There is even greater concern over the potential for unintended consequences brought about by the prescriptive requirements and subsequent enforcement from AHJ's on process cooling facilities, many of which serve a critical mission. One such prescriptive requirement is the application of economizers in many cases for Datacom facilities. Thus far, most Datacom facilities have gone without economizers, so there is little experience by end-users or design professionals alike on applying and operating economizers in mission critical facilities where extremely high availability and reliability are core requirements. Aside from the potential concerns surrounding gaseous and particulate contamination from the introduction of large quantities of outside air (ASHRAE TC9.9, 2009), there are also real concerns related to the design, construction, and operation of economizers that can result in unacceptable failure conditions (Quirk, 2010). This is not to detract from the numerous successful installations of economizers within Datacom facilities today, only to draw caution to the application given the additional complexities involved. Fortunately there are some exceptions to economizers for specific types of Datacom facilities, in addition to the alternative compliance paths within 90.1. This paper will attempt to outline the essential decision making processes for the application of economizers in Datacom facilities as well as outline how to navigate ANSI/ASHRAE/IESNA Standard-90.1 paths to energy code compliance for Datacom facilities.
机译:常设标准项目委员会(SSPC)已对ANSI / ASHRAE / IESNA Standard-90.1(低层住宅建筑除外的建筑物的能源标准)进行了修订,以在附录AQ批准后将数据中心纳入2010年版本的范围内。 Addenda BU也获得了批准,它为数据中心建立了一些特定的标准,包括对节能器的一些关键豁免。因此,任何采用2010版Standard-90.1的能源法规合规性的司法管辖区都将导致“数据通信”行业发生重大变化。在进行此更改之前,数据通信行业只能依靠自己的设备和能源效率策略的自由裁量权,近几年来,这种策略获得了巨大的动力,从而在能源效率方面进行了快速且值得注意的创新(Google博客,2010年)。 90.1中引入的更改引起了人们对基于规范的行业标准可能带来的创新压抑的担忧。规范性要求以及AHJ对过程冷却设备的后续执行带来的意料之外的后果的可能性引起了人们的更大关注,其中许多设备都担负着关键任务。这样的说明性要求之一是在许多情况下为Datacom设施使用节能器。迄今为止,大多数Datacom设施都没有节油器,因此最终用户或设计专业人员在将关键性设施(其中极高的可用性和可靠性是核心要求)应用和运行节油器方面经验很少。除了可能由于引入大量外界空气而引起的气体和颗粒物污染外(ASHRAE TC9.9,2009),还存在着与省煤器的设计,构造和运行有关的实际问题,这些问题可能导致不可接受的故障。条件(Quirk,2010)。这并不是要减损当今在Datacom设施中成功安装的众多节能器的成功,只是要考虑到所涉及的额外复杂性,对应用进行警告。幸运的是,除了90.1内的替代合规性途径外,某些类型的Datacom设施的节能器还有一些例外。本文将尝试概述在Datacom设施中使用节能器的基本决策过程,并概述如何导航ANSI / ASHRAE / IESNA Standard-90.1路径以符合Datacom设施的能源法规。

著录项

  • 来源
    《ASHRAE Transactions》 |2011年第2期|p.18-24|共7页
  • 作者

    David Quirk;

  • 作者单位

    Verizon Wireless, Basking Ridge, NJ;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号