A cryocooler assisted cryostat for a 4 T split-coil NbTi magnet operated in liquid helium bath is under development at the ANSALDO-CRIS. A two stage GM cryocooler (1st stage 15 W @ 45 K, 2nd stage 5 W @ 15 K) is used for the cooling of two radiation shields at temperatures less than 45 K and 15 K respectively. For magnet charge, a couple of 100 A vapor cooled HTS current leads, based on Bi-2223/AgAu tapes, operates between the 1st stage of cryocooler and the helium bath. AlN plates have been used to obtain a good thermal contact electrically insulated between HTS lead and cryocooler. The developed configuration allows to eliminate liquid nitrogen cooled radiation shields and to minimize static liquid helium consumption. Calculated and measured system performances are compared.
机译:ANSALDO-CRIS正在开发一种用于在液氦浴中运行的4 T分线圈NbTi磁体的低温冷却器辅助低温恒温器。两级GM低温冷却器(第一级15 W @ 45 K,第二级5 W @ 15 K)分别用于在温度低于45 K和15 K时冷却两个辐射屏蔽罩。对于磁体充电,基于Bi-2223 / AgAu胶带的一对100 A蒸气冷却的HTS电流引线在低温冷却器的第一级和氦浴之间运行。 AlN板已用于在HTS引线和低温冷却器之间获得良好的电绝缘电接触。开发的配置可以消除液氮冷却的辐射屏蔽,并最大程度减少静态液氦的消耗。比较了计算和测量的系统性能。