In the paper we present an analysis of AC losses in windings of a 14 kVA superconducting transformer with Bi-2223/Ag winding. AC losses of individual pancake coils of the secondary winding were measured. Discussion of the meaning of AC loss measurements in individual pancakes is presented. Measurement of loss in short samples (critical current in external magnetic field, transport current losses) was done and the results were compared with losses in the winding under operating conditions using available published data. An effect of temperature on winding losses was also studied.
机译:在本文中,我们对带有Bi-2223 / Ag绕组的14 kVA超导变压器的绕组中的交流损耗进行了分析。测量了次级绕组的各个煎饼线圈的交流损耗。讨论了煎饼中AC损耗测量的含义。测量了短样品的损耗(外部磁场中的临界电流,传输电流损耗),并使用公开的数据将结果与工作条件下绕组的损耗进行了比较。还研究了温度对绕组损耗的影响。