The magnet system of the Wendelstein 7-X stellarator (W7-X) consists of 50 nonplanar and 20 planar coils. In particular, the winding packs of the nonplanar coils are densely packed and compressed in the area of inter-layer joints and coil terminations, which brings some risk of inter-turn and inter-layer short circuits. The paper describes methods deducted from impulse and ac tests performed on the coils, which enable demonstrating the absence of short circuits and weak points of low inter-layer insulation resistance. In the impulse test, frequency and damping are compared for coils with and without short circuits and coils with an external low resistance bypass. With ac voltage, a drastically reduced impedance clearly indicates a short circuit. Therefore both tests represent excellent QA (quality assurance) tools for checking the uniformity of the electromagnetic performance of a serial production of magnet coils.
机译:Wendelstein 7-X恒星器(W7-X)的磁体系统由50个非平面线圈和20个平面线圈组成。特别地,非平面线圈的绕组在层间接头和线圈终端的区域中被密集地包装和压缩,这带来了匝间和层间短路的风险。本文介绍了从对线圈进行的脉冲和交流测试中得出的方法,这些方法可以证明没有短路和低层间绝缘电阻的弱点。在脉冲测试中,比较了带短路和不带短路的线圈以及带有外部低电阻旁路的线圈的频率和阻尼。在交流电压下,阻抗急剧降低明显表明发生了短路。因此,这两个测试均代表了出色的QA(质量保证)工具,可用于检查批量生产的电磁线圈的电磁性能是否均匀。