首页> 外文期刊>IEEE Transactions on Applied Superconductivity >Electrical Design Requirements on the ITER Coils
【24h】

Electrical Design Requirements on the ITER Coils

机译:ITER线圈的电气设计要求

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The ITER coils are all designed using superconducting conductors with a high current carrying capability. Plasma operation and control requires fast variation of the currents in the pulsed coils inducing more than 10 kV during normal operation on the coil terminals. The power supplies are designed to limit the high voltages, but under short conditions, voltages may rise above 20 kV in certain coils. Moreover, the acceptance tests of the coils must be carried out at higher voltages, up to 28 kV for the CS coils. The electrical design philosophy of the coils includes recovery options in the event of electrical faults internal to the coils.
机译:ITER线圈均使用具有高载流能力的超导导体进行设计。等离子体操作和控制要求脉冲线圈中的电流快速变化,从而在正常运行期间在线圈端子上感应出超过10 kV的电压。电源设计用于限制高电压,但是在短期条件下,某些线圈中的电压可能会上升到20 kV以上。此外,线圈的验收测试必须在更高的电压下进行,对于CS线圈,最高电压为28 kV。线圈的电气设计原理包括在线圈内部发生电气故障时的恢复选项。